Background: Acute ankle diastasis injuries are complex and debilitating. These injuries occur when the syndesmotic complex becomes compromised. Treatments of acute syndesmotic injuries include static fixation with screws, dynamic fixation with an elastic device, or anatomic repair of the damaged ligament. However, there is disagreement over which method is most effective. The primary purpose of this study was to compare the 3 treatment methods for acute syndesmotic injuries.

Methods: A systematic literature search was conducted on Embase and PubMed. Studies that compared at least 2 groups with relevant American Orthopaedic Foot & Ankle Society (AOFAS), Visual Analog Scale (VAS), reoperation rate, and complication (implant failure, implant irritation, and infection) data were analyzed. Statistical analysis for this study was performed using Review Manager 5.4, with a standard p-value of ≤0.05 for statistical significance.

Results: Twenty-one studies including a total of 1,059 patients (452 dynamic, 529 static, and 78 anatomic) were included for analysis. Dynamic fixation had significantly higher mean AOFAS scores at 3 months postoperation by 5.12 points (95% confidence interval [CI], 0.29-9.96, p = 0.04) as well as at 1 year postoperation by 4.64 points (95% CI, 1.74-7.55, p = 0.002) than static fixation. Anatomic repair had significantly higher AOFAS scores at 6 months postoperation by 3.20 points (95% CI, 1.06-5.34, p = 0.003) and 1 year postoperation by 1.86 points (95% CI, 0.59-3.14, p = 0.004) than static fixation. Dynamic fixation had significantly higher AOFAS scores at 6 months postoperation by 2.81 points (95% CI, 0.76-4.86, p = 0.007), 12 months postoperation by 3.17 points (95% CI, 0.76-5.58, p = 0.01), and at 2 years postoperation by 5.56 points (95% CI, 3.80-7.32, p < 0.001) than anatomic repair. Dynamic fixation also had a lower VAS score average (favorable), only significant at 12 months postoperation, than static fixation by 0.7 points (95% CI -0.99 to -0.40, p < 0.001). Anatomic repair did not have significant difference in VAS scores compared with static fixation. Anatomic repair had significantly lower VAS scores at 12 months postoperation by 0.32 points (95% CI -0.59 to -0.05, p = 0.02) than dynamic fixation. Dynamic fixation had significantly less implant failures (odds ratio [OR], 0.13, 95% CI, 0.05-0.32, p < 0.001) than static fixation. Anatomic repair was not significantly different from static fixation in the complication metrics. Dynamic fixation and anatomic repair were not significantly different in the complication metrics either. Dynamic fixation had a significantly lower reoperation rate than static fixation (OR, 0.23, 95% CI, 0.09-0.54, p < 0.001). Anatomic repair did not have a significantly different reoperation rate compared with static fixation. However, dynamic fixation had a significantly lower reoperation rate than anatomic repair (OR, 4.65, 95% CI, 1.10-19.76, p = 0.04).

Conclusion: Dynamic fixation seems to demonstrate superior early clinical outcomes. However, these advantages become negligible in the long term when compared with alternative options. Dynamic fixation is associated with a lower risk for complications, specifically seen with the decrease in implant failures. This method also presents a significantly lower reoperation rate compared with the other treatment approaches. Apart from showing improved early clinical outcomes in comparison with static fixation, anatomic repair did not have significant distinctions in other metrics, including complications or reoperation rate.

Level Of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.RVW.24.00031DOI Listing

Publication Analysis

Top Keywords

static fixation
44
anatomic repair
44
dynamic fixation
44
points 95%
36
fixation anatomic
24
months postoperation
24
fixation
22
reoperation rate
20
scores months
16
dynamic
13

Similar Publications

Background: Iatrogenic suprascapular nerve injury secondary to posterior drilling or screw penetration is a recognized complication of bone block or coracoid process transfers for anterior glenohumeral instability. We present the first cadaveric study that assesses the safety of posteroanterior reference guides and quantifies the relationship of the suprascapular nerve to posterior glenoid fixation with suture buttons.

Methods: Anterior glenoid bone block reconstruction with suture buttons utilizing a posteroanterior reference guide was performed in 10 fresh frozen cadavers via a posterior portal.

View Article and Find Full Text PDF

Analysis of the distribution of mechanical load on the plate and lateral hinge of a valgus-producing open wedge high tibial osteotomy during weight-bearing by simulating consolidation. Finite element study.

Orthop Traumatol Surg Res

December 2024

Laboratoire ICube, Université de Strasbourg - CNRS, 4 rue de la Manufacture des Tabacs, 67000 Strasbourg, France; Service de Chirurgie Orthopédique et de Traumatologie, Hôpital de Hautepierre II, 1 Avenue Molière, 67098 Strasbourg Cedex, France. Electronic address:

Introduction: High tibial osteotomy (HTO) is indicated for managing isolated medial knee osteoarthritis in a young patient with a metaphyseal deformity of the proximal tibia. In a medial open-wedge HTO, maintaining the integrity of the hinge is crucial for consolidation and preservation of the correction. Based on a validated model and preliminary results, the objective of this work was to measure and monitor the distribution of mechanical load on a locking fixation plate and the lateral hinge of an HTO using a finite element (FE) model during different phases of consolidation evolution, simulating single leg weightbearing.

View Article and Find Full Text PDF

The present study aimed to investigate changes in corticospinal excitability (CSE) by observing unnatural walking patterns on a treadmill with different left and right belt speeds. Fifteen healthy adults watched video clips (10 s each) of walking under the tied condition (left and right treadmill belt speeds are the same), walking during the initial and late periods under the split-belt condition (left and right treadmill belt speeds are different), and the static fixation cross (control condition) in random order. The step lengths of the actor in the walking clips were almost symmetric under the tied condition and during the late period under the split-belt condition but largely asymmetric during the initial period under the split-belt condition.

View Article and Find Full Text PDF

Background: Effects of rigid posterior instrumentation on the three-dimensional post-operative spinal flexibility are widely unknown. Purpose of this in vitro study was to quantify these effects for characteristic adolescent idiopathic scoliosis instrumentations.

Methods: Six fresh frozen human thoracic and lumbar spine specimens (C7-S) with entire rib cage from young adult donors (26-45 years) without clinically relevant deformity were loaded quasi-statically with pure moments of 5 Nm in flexion/extension, lateral bending, and axial rotation.

View Article and Find Full Text PDF

Purpose: This study evaluates differences in the visual field performance when wearing the Defocus Incorporated Multiple Segments (DIMS) spectacle lens compared to wearing a conventional single vision (SV) spectacle lens.

Methods: Twenty-one children aged 9-14 years with spherical equivalent refraction (SER) between -1.13D to -4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!