A finite element model of cervical kyphosis was established to analyze the stress of cervical spine under suspensory traction and to explore the mechanism and effect of it. A patient with typical cervical kyphosis (C2-C5) underwent CT scan imaging, and 3D slicer was used to reconstruct the C2 to T2 vertebral bodies. The reconstructed data was imported into Hypermesh 2020 and Abaqus 2017 for meshing and finite element analysis. The changes of the kyphotic angle and the von Mises stress on the annulus fibrosus of each intervertebral disc and ligaments were analyzed under suspensory traction conditions. With the increase of suspensory traction weight, the overall kyphosis of cervical spine showed a decreasing trend. The correction of kyphosis was mainly contributed by the change of kyphotic segments. The kyphotic angle of C2-C5 was corrected from 45° to 13° finally. In cervical intervertebral discs, the stress was concentrated to anterior and posterior part, except for C4-5. The stress of the anterior longitudinal ligament (ALL) decreased from the rostral to the caudal, and the high level von Mises stress of the kyphotic segments appeared at C2-C3, C3-C4, and C4-C5. The roles of the other ligaments were not obvious. The kyphotic angle was significantly reduced by the suspensory traction. Shear effect due to the high von Mises stress in the anterior and posterior parts of annulus fibrosus and the tension on the anterior longitudinal ligament play a role in the correction of cervical kyphosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11330378PMC
http://dx.doi.org/10.1007/s11517-024-03113-zDOI Listing

Publication Analysis

Top Keywords

suspensory traction
20
cervical kyphosis
16
finite element
12
kyphotic angle
12
von mises
12
mises stress
12
element analysis
8
cervical spine
8
annulus fibrosus
8
kyphotic segments
8

Similar Publications

Penile Enhancement Surgery-The Short and the Long of It.

Urology

November 2024

Division of Urology, Department of Surgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ. Electronic address:

Article Synopsis
  • Penile augmentation reflects human creativity in medical science, with a historical overview of enhancement methods such as snake bites, herbs, and traction therapy in ancient times.
  • Modern techniques now include injectable fillers and grafting for increasing girth, while lengthening methods involve V-Y advancement and suspensory ligamentolysis.
  • Despite potential size gains from these strategies, there are risks of complications and variable psychological effects on patient satisfaction.
View Article and Find Full Text PDF

A finite element model of cervical kyphosis was established to analyze the stress of cervical spine under suspensory traction and to explore the mechanism and effect of it. A patient with typical cervical kyphosis (C2-C5) underwent CT scan imaging, and 3D slicer was used to reconstruct the C2 to T2 vertebral bodies. The reconstructed data was imported into Hypermesh 2020 and Abaqus 2017 for meshing and finite element analysis.

View Article and Find Full Text PDF

Cosmetic penile enhancement procedures: an SMSNA position statement.

J Sex Med

May 2024

Department of Urology, Mayo Clinic, 200 First St. SW Rochester, MN 55905, United States.

Background: Penile cosmetic enhancement procedures have been performed for many years with varying success. However, they have historically been relegated to niche areas of sexual medicine, with limited data, and have not achieved mainstream adoption. More recently, the topic has been increasingly discussed within academic congresses due to availability of novel techniques, therapies, and procedures.

View Article and Find Full Text PDF

Background: Little is known about the stability of adjustable-loop devices (ALDs) for anterior cruciate ligament (ACL) reconstruction (ACLR).

Purpose: To evaluate the stabilization behavior of 3 different types of ALDs for all-inside ACLR in a full-construct surgical technique-based manner.

Study Design: Controlled laboratory study.

View Article and Find Full Text PDF

The purpose of our biomechanical study was to assess load-to-failure, stiffness, gap formation following cyclic loading, and the failure mechanism for anterior cruciate ligament (ACL) repair comparing the cortical suspensory button and knotless anchor suture. Eight Thiel's embalmed paired cadaveric knees from four cadavers were dissected. The specimens were assigned to undergo ACL repair either with cortical suspensory button or with knotless anchor suture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!