Prcis: This systematic review and meta-analysis concludes that the PreserFlo Microshunt glaucoma drainage device significantly reduces intraocular pressure in primary open angle glaucoma patients at 12 months postinsertion.

Purpose: A systematic review and meta-analysis on the effect of the PRESERFLO MicroShunt (PF-MS) on intraocular pressure (IOP) at 12 months has been conducted.

Method: The PubMed/MEDLINE, Embase, CENTRAL, Google Scholar, Scopus, and Web of Science databases were searched. Inclusion criteria required a diagnosis of open angle glaucoma, PF-MS insertion, and examination of IOP over time. Meta-analyses were conducted on the primary outcome of IOP and the secondary outcome of glaucoma medication regime. Adverse events were also noted.

Results: Fourteen studies were identified for inclusion in the meta-analyses, of which none had a high risk of bias. The meta-analyses found a significant mean reduction in IOP of 9.07 mm Hg (95% CI: 7.88-10.25; P <0.0001) and a significant mean reduction in mean glaucoma medication requirement of 2.37 medications (95% CI: 2.15-2.60; P <0.0001). Hypotony and hyphaema are common early complications.

Conclusions: The PF-MS device significantly reduced both IOP and glaucoma medication requirement at 12 months postinsertion in individuals with open angle glaucoma without a significant adverse event burden. Further research is required to determine the economic and environmental effects of widely implementing the PF-MS device into clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000002419DOI Listing

Publication Analysis

Top Keywords

preserflo microshunt
12
open angle
12
angle glaucoma
12
systematic review
12
review meta-analysis
12
primary open
8
intraocular pressure
8
glaucoma
5
one-year outcomes
4
outcomes preserflo
4

Similar Publications

Preserflo MicroShunt (PMS) implantation is a minimally invasive surgical procedure for treating glaucoma. Postoperative hypotony, a common complication of PMS implantation, can be prevented and treated with 10-0 nylon insertion. In this report, we present a case of postoperative hypotony following PMS implantation that was treated with intraluminal insertion of 9-0 nylon.

View Article and Find Full Text PDF

Purpose: To investigate the efficacy and safety of the Preserflo MicroShunt (PMS) in treating glaucoma secondary to different uveitic glaucoma (UG) types in a European population.

Methods: This study evaluated consecutive eyes with UG that received the PMS. The primary outcome measure was 12-month surgical success (≥20% IOP reduction, target IOP of 6-21 mmHg).

View Article and Find Full Text PDF

Glaucoma and cataract often coexist. Patients with both conditions who qualify for surgical treatment may undergo either a combined surgical procedure or sequential treatments such as cataract surgery followed by an antiglaucoma procedure. A combined procedure with phacoemulsification is related to an increased risk of fibrosis of the filtering bleb; however, it is a rational approach for patients with high intraocular pressure and clinically significant lens opacification.

View Article and Find Full Text PDF

A 74-year-old Japanese woman with a history of primary open-angle glaucoma (POAG) in both eyes underwent PreserFlo MicroShunt (PFM) (Osaka, Japan: Santen Pharmaceutical, Co., Ltd.) implantation two years prior.

View Article and Find Full Text PDF

A 59-year-old Japanese woman with primary open-angle glaucoma underwent PreserFlo MicroShunt (PFM) (Santen Pharmaceutical Co., Ltd., Osaka, Japan) implantation in her left eye.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!