Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Miniaturized and microstructured reactors in process engineering are essential for a more decentralized, flexible, sustainable, and resilient chemical production. Modern, additive manufacturing methods for metals enable complex reactor-geometries, increased functionality, and faster design iterations, a clear advantage over classical subtractive machining and polymer-based approaches. Integrated microsensors allow online, in situ process monitoring to optimize processes like the direct synthesis of hydrogen peroxide. We developed a modular tube-in-tube membrane reactor fabricated from stainless steel via 3D printing by laser powder bed fusion of metals (PBF-LB/M). The reactor concept enables the spatially separated dosage and resaturation of two gaseous reactants across a membrane into a liquid process medium. Uniquely, we integrated platinum-based electrochemical sensors for the online detection of analytes to reveal the dynamics inside the reactor. An advanced chronoamperometric protocol combined the simultaneous concentration measurement of hydrogen peroxide and oxygen with monitoring of the sensor performance and self-calibration in long-term use. We demonstrated the highly linear and sensitive monitoring of hydrogen peroxide and dissolved oxygen entering the liquid phase through the membrane. Our measurements delivered important real-time insights into the dynamics of the concentrations in the reactor, highlighting the power of electrochemical sensors applied in process engineering. We demonstrated the stable continuous measurement over 1 week and estimated the sensor lifetime for months in the acidic process medium. Our approach combines electrochemical sensors for process monitoring with advanced, additively manufactured stainless steel membrane microreactors, supporting the power of sensor-equipped microreactors as contributors to the paradigm change in process engineering and toward a greener chemistry.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11064172 | PMC |
http://dx.doi.org/10.1021/acsomega.4c02210 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!