A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A case report of entrapment of PentaRay catheter in the mechanical mitral valve: a known complication experienced anew. | LitMetric

A case report of entrapment of PentaRay catheter in the mechanical mitral valve: a known complication experienced anew.

Eur Heart J Case Rep

Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan 2nd Road, Yuexiu District, 510000 Guangzhou, China.

Published: May 2024

Background: Complex atrial tachycardia (AT) is commonly observed in patients with cardiac surgery. High-density mapping is widely adopted for catheter ablation of complex AT in patients with cardiac surgery. Several case reports have described that PentaRay mapping catheter can be trapped in the mechanical valve and sheared off and successful retrieval of the spline by a snare system. We described a rare case in which PentaRay mapping catheter spline was successfully retrieved from the distal anterior tibial artery by direct syringe suction via the diagnostic catheter following entrapment in the mechanical mitral valve (MV) and rupture of the spline.

Case Summary: A 70-year-old female with mechanical bileaflet MV underwent catheter ablation for AT. During mapping in left atrium, the catheter was entrapped in mechanical MV and sheared off. We attempted to release the entrapped the spline by advancing the ablation catheter towards the stuck disc and pushing on the hinge portion of the disc with the catheter tip. The stuck and closed disc was opened, and the deeply entrapped spline was released. However, the entrapped PentaRay spline floated through the Valsalva sinus and strayed into the distal left anterior tibial artery. Fortunately, we successfully retrieved the spline from the distal anterior tibial artery by direct syringe suction instead of a snare system.

Discussion: The possibility of the entrapment and subsequent rupture of the spline should always be considered during mapping the site close to mechanical valve. A rapid retrieval of embolized material should be carried out. If the spline strays into the distal and small artery in which the snare system is difficult to advance, a direct syringe suction via the diagnostic catheter may be attempted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11065343PMC
http://dx.doi.org/10.1093/ehjcr/ytae194DOI Listing

Publication Analysis

Top Keywords

anterior tibial
12
tibial artery
12
direct syringe
12
syringe suction
12
catheter
10
mechanical mitral
8
mitral valve
8
patients cardiac
8
cardiac surgery
8
catheter ablation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!