A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Analysis of clinical effect of arthroscopic release at different time in treating knee adhesion after arthroscopic surgery]. | LitMetric

[Analysis of clinical effect of arthroscopic release at different time in treating knee adhesion after arthroscopic surgery].

Zhonghua Yi Xue Za Zhi

Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing Key Laboratory of Sports Injuries, Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing 100191, China.

Published: May 2024

To explore the efficacy of arthroscopic release in treating postoperative knee adhesion and investigate the influence of release timing on the treatment outcomes. A total of 50 patients who accepted arthroscopic release in Peking University Third Hospital from February 2017 to December 2021 were included in the retrospective cohort. The study cohort comprised 28 men and 22 women, with a mean age of (30.8±11.9) years. All the primary surgeries were manipulated under arthroscopes. A comparison was made between pre-and postoperative range of motion (ROM), visual analog scale (VAS), International Knee Documentation Committee (IKDC) scores, and Tegner activity scale scores for the patients. According to the interval between the appearance of adhesion and arthroscopic release, the patients were divided into four groups:<3 months group (=12), 3-6 months group (=16),>6-12 months group (=14), and>12 months group (=8). Inter-group comparisons on postoperative ROM, IKDC scores, and Tegner activity scale scores and improvement values of each outcome were conducted. All the patients were followed up for (36.4±19.7) months. Patients gained significant improvement in flexion, extension, IKDC scores, and Tegner scores (125.0°±20.0° vs 75.7°±27.5°, 2.3°±4.8° vs 7.4°±7.3°, 69.8±17.7 vs 51.4±12.8, 4.1±2.1 vs 2.2±1.1) (all <0.05), while the VAS scores did not show significant improvement. There were no significant differences among different groups in postoperative extension, IKDC scores or Tegner scores, nor in their improvements. However, patients in the ≤6 months group could gain better postoperative flexion and improvement in flexion than those in the >6 months group (129.9°±20.0° vs 118.8°±17.4°, 58.6°±32.8° vs 37.3°±23.1°) (<0.05). Arthroscopic release presents a great effect in treating knee adhesion after arthroscopic operation. Once the symptoms of adhesion appear and physical rehabilitation fails to improve the ROM, one should accept early surgical intervention (less than 6 months) for a better outcome.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn112137-20231021-00844DOI Listing

Publication Analysis

Top Keywords

arthroscopic release
16
ikdc scores
12
scores tegner
12
months group
12
knee adhesion
8
adhesion arthroscopic
8
tegner activity
8
activity scale
8
scale scores
8
scores
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!