Utility of a modified o-DGT passive sampler for measurement of bisphenol analogues in freshwater and coastal waters.

Sci Total Environ

Key Laboratory of Pollution Control and Ecosystem Restoration in Industry Clusters (Ministry of Education), School of Environment and Energy, South China University of Technology, Guangzhou 510006, China. Electronic address:

Published: June 2024

Bisphenol analogues (BPs) are commonly found in riverine and coastal waters. However, the lack of a reliable and robust passive sampling method has hindered our ability to monitor these compounds in aquatic systems. The study developed a novel organic-diffusive gradients in thin film (o-DGT) sampler based on stainless steel mesh membrane, polyacrylamide diffusive gel, and hydrophilic-lipophilic balance (HLB) binding gel. This innovative design tackled issues of filter membrane sorption in traditional o-DGT devices and potential gel damage in membrane-less o-DGT devices, showing promising application prospects. The mass accumulation of 15 target BPs was linear over 10 days in both freshwater (r ≥ 0.92) and seawater (r ≥ 0.94), with no saturation observed. The diffusion coefficients (D) through polyacrylamide diffusive gels ranged from 4.04 × 10 to 5.77 × 10 cm s in freshwater and from 1.74 × 10 to 4.69 × 10 cm s in seawater for the target BPs (except for bisphenol PH) at 22 °C. The D values of the target BPs in seawater were lower than those in freshwater due to the high salinity in seawater (35 ‰). The o-DGT samplers demonstrated good integrity in field applications. The total concentrations of the eight detected BPs ranged from 9.2 to 323 ng L, which was consistent with the measurements obtained by grab sampling. Among all BPs, bisphenol S, bisphenol F, and bisphenol A were consistently detected at all sites using both sampling methods. The concentrations of some novel BPs in coastal water measured by grab sampling were comparable to those measured in rivers, suggesting the need to strengthen pollution control of BPs in coastal areas. These results indicate that the o-DGT passive sampling method developed in the present study can be effectively used for monitoring BPs in freshwater and coastal environments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2024.172978DOI Listing

Publication Analysis

Top Keywords

target bps
12
bps
9
o-dgt passive
8
bisphenol analogues
8
freshwater coastal
8
coastal waters
8
passive sampling
8
sampling method
8
polyacrylamide diffusive
8
o-dgt devices
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!