Evaluation of post-PCR purification methods and subsequent optimisation of the MinElute® PCR Purification Kit for low input DNA samples amplified with PowerPlex® 21.

Forensic Sci Int

Forensic Biology Department, PathWest Laboratory Medicine, Perth, WA, Australia. Electronic address:

Published: July 2024

Weak and partial DNA profiles are commonly encountered within forensic casework due to amplification of low DNA input samples. One option for increasing allelic detection in such samples is the purification of amplified PCR product using commercially available column-based methods. In this study, four commercially available post-PCR purification methods, QIAGEN MinElute®, Independent Forensics Amplicon™ Rx, Millipore Microcon® and Thermo Fisher Scientific ExoSAP-IT™ were evaluated, comparing the quality of PowerPlex® 21 DNA profiles produced to the standard DNA profile generated prior to purification. An increased detection of alleles above the analytical threshold was observed following purification with the MinElute®, Amplicon™ Rx and Microcon® methods, allowing informative DNA profiles to be recovered using as little as 8 pg DNA. However, post-PCR purification using the ExoSAP-IT™ kit was unsuccessful, with no alleles detected above analytical threshold in samples with ≤16 pg DNA. The MinElute® kit was selected for optimisation on the basis of DNA profile quality, including increased detection of alleles and minimal artefacts. The MinElute® method was optimised by evaluating the number of washes and final elution buffer volume, resulting in a further increase in detection of alleles by reducing the elution buffer volume. Overall, this study showed that PowerPlex® 21 DNA profiles from low input DNA can be successfully enhanced by employing the MinElute® post-PCR purification method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.forsciint.2024.112043DOI Listing

Publication Analysis

Top Keywords

post-pcr purification
16
dna profiles
16
detection alleles
12
dna
11
purification
8
purification methods
8
low input
8
input dna
8
powerplex® dna
8
dna profile
8

Similar Publications

Background: While Streptococcus pneumoniae (Spn) is the leading cause of pediatric complicated community-acquired pneumonia (cCAP), it is infrequently recovered by culture-based methods. We studied the real-world clinical impact of an Spn polymerase chain reaction (PCR) assay for pleural fluid.

Methods: This pre-post quasi-experimental cohort study compared pathogen detection, antibiotic usage, and outcomes in children hospitalized with cCAP requiring pleural effusion or empyema drainage at Children's Hospital Colorado between 2016 and 2023.

View Article and Find Full Text PDF

High-resolution melting curve analysis: A detection assay for Ceratocystis eucalypticola and C. manginecans in infected Eucalyptus.

Fungal Biol

October 2024

Department of Biochemistry, Genetics and Microbiology, Forestry and Agricultural Biotechnology Institute (FABI), University of Pretoria, Private Bag X20, Pretoria, 0028, South Africa. Electronic address:

Eucalyptus spp. in plantations are negatively affected by canker and wilt diseases caused by several species of Ceratocystis, particularly those in the Latin American Clade (LAC). Ceratocystis eucalypticola and Ceratocystis manginecans are of particular concern where disease epidemics are reported globally, with recent outbreaks emerging in South African and Indonesian Eucalyptus plantations.

View Article and Find Full Text PDF

The generation of high-quality DNA profiles from trace amounts of DNA continues to be an issue in forensic casework. Several methods have been proposed over the years to increase recovery rates for low input DNA, including purification of PCR products, an increase in PCR cycle numbers and increasing injection time or voltage during electrophoresis. In this study, the characteristics of DNA profiles generated using QIAGEN MinElute® purification of Promega PowerPlex® 21 amplified products for low DNA input samples, ranging from 80 pg down to 4 pg, were evaluated.

View Article and Find Full Text PDF

Weak and partial DNA profiles are commonly encountered within forensic casework due to amplification of low DNA input samples. One option for increasing allelic detection in such samples is the purification of amplified PCR product using commercially available column-based methods. In this study, four commercially available post-PCR purification methods, QIAGEN MinElute®, Independent Forensics Amplicon™ Rx, Millipore Microcon® and Thermo Fisher Scientific ExoSAP-IT™ were evaluated, comparing the quality of PowerPlex® 21 DNA profiles produced to the standard DNA profile generated prior to purification.

View Article and Find Full Text PDF

Cleaning protocols in forensic genetic laboratories.

Int J Legal Med

September 2024

Section of Forensic Genetics, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

It is pivotal to avoid cross-sample contamination in forensic genetic laboratories and optimal cleaning protocols for the removal of DNA are essential. A survey was performed, and ten forensic genetic laboratories shared their cleaning protocols in pre-PCR and post-PCR laboratories. The cleaning frequencies on different surface areas were somewhat similar, whereas none of the laboratories used the same cleaning reagents.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!