A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of Response Surface Approach for Determination of Paracetamol, Chlorpheniramine Maleate, Caffeine and Ascorbic Acid by Green HPLC Method: A Desirability-Based Optimization. | LitMetric

Design of experiment is an efficient and cost-effective tool to optimize the chromatographic separation of a multicomponent mixture. The central composite design was conducted to develop and optimize a green high performance liquid chromatography (HPLC) method for simultaneous quantitation of a quaternary mixture of paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid in their pharmaceutical dosage form as well as the determination of their dissolution profile. A five-level three-factor model was performed to investigate the effect of mobile phase composition, pH and flow rate on enhanced resolution and short run time. Analysis was performed using a Kinitex EVO C18 column and a mobile phase composed of methanol: 0.02 M phosphate buffer pH 3.3 (34:66, v/v) at 1.0 mL/min using photodiode array detection. Optimum chromatographic separation was achieved in <6 min with a desirability of 0.999. Linearity was achieved over a range of 1.00-300.00, 1.00-50.00, 2.00-50.00 and 2.00-100.00 μg/mL for paracetamol, chlorpheniramine maleate, caffeine and ascorbic acid, respectively, with a limit of detection (<0.1 μg/mL). The greenness profile was evaluated using the analytical eco-scale and Analytical GREEnness Metric Approach with values of 81 and 0.77, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmae024DOI Listing

Publication Analysis

Top Keywords

paracetamol chlorpheniramine
8
chlorpheniramine maleate
8
maleate caffeine
8
caffeine ascorbic
8
ascorbic acid
8
hplc method
8
chromatographic separation
8
mobile phase
8
development response
4
response surface
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!