The peak force to push a trial tibial insert into position cannot be used to select the correct thickness in total knee arthroplasty.

Arch Orthop Trauma Surg

Department of Biomedical Engineering, Department of Mechanical Engineering, Department of Orthopaedic Surgery, University of California Davis, Davis, CA, 95616, US.

Published: June 2024

An objective of a total knee arthroplasty (TKA) is to restore native (i.e. healthy) function, and a crucial step is determining the correct insert thickness for each patient. If the insert is too thick, then stiffness results, and if too thin, then instability results. Two methods to determine the insert thickness are by manually assessing the joint laxity and by using a trial insert with goniometric markings that measures the internal-external rotation of the trial with respect to a mark on the femoral component. The former is qualitative and depends on the surgeon's experience and 'feel' and while the latter is quantitative, it can be used only with an insert with medial ball-in-socket conformity. An unexplored method is to measure the force required to push a trial insert into position. To determine whether this method has merit, the push force was measured in 30 patients undergoing unrestricted kinematically aligned TKA using an insert with ball-in-socket medial conformity, a flat lateral surface, and retention of the posterior cruciate ligament. During surgery, the surgeon determined three appropriate thicknesses to test from a selection ranging from 10 mm to 14 mm in 1 mm increments. The peak push forces going from an insert 1 mm thinner than the correct thickness as determined by an insert goniometer and from the correct thickness to 1 mm thicker were measured. Mean peak forces for the different insert thicknesses were 127 ± 104 N, 127 ± 95 N, and 144 ± 96 N for 1 mm thinner, correct, and 1 mm thicker, respectively, and did not differ (p = 0.3210). As a result, measurement of peak force during trial positioning of a tibial insert cannot be used to identify the correct thickness for all insert designs.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-024-05313-6DOI Listing

Publication Analysis

Top Keywords

correct thickness
16
insert
13
peak force
8
push trial
8
tibial insert
8
insert position
8
total knee
8
knee arthroplasty
8
insert thickness
8
trial insert
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!