A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of bone levels on stress distribution around all-on-four concept: A 3-D finite element analysis. | LitMetric

Impact of bone levels on stress distribution around all-on-four concept: A 3-D finite element analysis.

J Stomatol Oral Maxillofac Surg

Hacettepe University Faculty of Dentistry, Oral and Maxillofacial Surgery Department, Ankara, Turkey.

Published: September 2024

This study aimed to investigate the impact of implant placement levels within the bone on stress distribution in the context of the All-on-Four concept. In this Finite Element Analysis(FEA), two 4.1 mm x 10 mm implants were axially placed in the anterior region of the jawbone, while two 4.1 mm x 14 mm implants were tilted at 30 ° in the posterior region following the all-on-four concept. In the EC scenario, all implants were inserted at the equicrestal level. In other scenarios, implants were positioned at 1 mm and 2 mm subcrestal levels (SC1, SC2). In all groups, the prosthesis was designed to replicate a group-function occlusion. A total load of 450 N was applied to the prosthesis. Upon deeper implant placement below the crest level, a trend of decreasing Von Mises stresses was observed in both implants and implant fragments. The highest Pmax value in the bone was recorded in SC-2, characterized by the absence of cortical bone support, with values of 3.16 N/mm in the anterior region and 1.55 N/mm in the posterior region. Conversely, the lowest Pmax values were noted in SC-1 for the anterior implant (2.67 N/mm) and the EC for the posterior implant (0.87 N/mm). Implant placements devoid of cortical bone support result in stress transmission from the implant and its components to the peri-implant bone. Optimal stress minimization is achieved by placing anterior axial angle implants deeper than the crest level while retaining cortical bone support and positioning posterior tilted implants at the crest level.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jormas.2024.101905DOI Listing

Publication Analysis

Top Keywords

all-on-four concept
12
crest level
12
cortical bone
12
bone support
12
stress distribution
8
finite element
8
implant placement
8
anterior region
8
posterior region
8
n/mm posterior
8

Similar Publications