Purpose: To compare the quality of images of gratings placed in a model eye viewed through an extended depth of focus (EDoF) intraocular lens (IOL) to that of diffractive bifocal IOL or monofocal IOL.

Design: Experimental laboratory investigation.

Methods: Nondiffractive wavefront shaping EDoF (CNAET0, Alcon Laboratories), echelette-designed EDoF (ZXR00V, Johnson & Johnson Vision), diffractive bifocal IOL with low power addition (SV25T, Alcon Laboratories), or monofocal IOL (CNA0T0, Alcon Laboratories) was placed in a fluid-filled model eye. A United States Air Force Resolution Grating Target was glued to the posterior surface of the model eye and viewed through a flat or a wide-angle contact lens. The contrast of the gratings viewed through the EDoF or multifocal IOLs was compared to that through the monofocal IOL. A wavefront analyzer was used to measure the spherical power of the central 4.5 mm optics of the EDoF, multifocal, and monofocal IOLs. The distribution of the dioptric power and the dioptric power map were compared.

Results: The gratings observed through the flat contact lens with CNAET0, ZXR00V, or SV25T were slightly blurred when viewed through the multifocal optics. The blurred area was in the circumferential area of CNAET0, the central area of SV25T, and the peripheral area of ZXR00V. The mean contrast was 0.258 ± 0.020 for CNAET0, 0.227 ± 0.025 for ZXR00V, and 0.221 ± 0.020 for SV25T for the 16.0 cyc/mm grating. The contrast was significantly lower for ZXR00V (P = .004) and SV25T (P = .004) than 0.303 ± 0.015 for CNA0T0 but the differences were not significant for CNAET0. For the wide-angle contact lens, the contrast for CNAET0 was 0.182 ± 0.009, for ZXR00V was 0.162 ± 0.011, and for SV25T was 0.163 ± 0.007 for the 16.0 cyc/mm grating, and none was significantly different from 0.188 ± 0.012 for CNA0T0. The dioptric variations of CNAET0 indicated a ring-shaped area of higher power corresponding to the circumferential blurred zone observed through the flat contact lens.

Conclusions: The wavefront shaping and echelette-designed EDoF-IOLs reduce the contrast of the grating more than the monofocal IOL when viewed through the flat contact lens. The degree of reduction depended on the design of the extended-focus optics. The difference was less through the wide-angle contact lens.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2024.04.028DOI Listing

Publication Analysis

Top Keywords

contact lens
20
model eye
16
wavefront shaping
12
alcon laboratories
12
monofocal iol
12
wide-angle contact
12
flat contact
12
extended depth
8
depth focus
8
intraocular lens
8

Similar Publications

[Ophthalmic oncology in a warmer world: climate-related increase in the prevalence of eyelid cancer].

Ophthalmologie

January 2025

Klinik für Augenheilkunde, Klinikum Chemnitz, Flemmingstr. 2, 09116, Chemnitz, Deutschland.

Background: Damage induced by ultraviolet (UV) radiation plays a decisive role in the carcinogenesis of malignant tumors of the eyelids.

Methods: A selective literature search was performed in PubMed and Google Scholar.

Results: Large epidemiological studies show an increase in the prevalence of eyelid tumors in recent decades.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the effect of hypoxia and hypobaric conditions on refraction and central corneal thickness on healthy corneas during an ascent without oxygen supplementation above 7000 m (23 000 ft).

Methods: Twelve multinational mountaineers were included in a prospective observational cohort study during an expedition to the Korzhenevskoi Peak (7105 m). The two patients excluded from the study had a history with keratoconus or were current wearers of rigid contact lenses.

View Article and Find Full Text PDF

Quarter of a century of contact lens prescribing trends in Australia (2000-2024).

Clin Exp Optom

January 2025

Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.

Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.

Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.

Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.

View Article and Find Full Text PDF

Corneal first aid lens: Collagen-based hydrogels loading aFGF as contact lens for treating corneal injuries.

J Control Release

January 2025

Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health), Cixi Biomedical Research Institute, School of Pharmaceutical Sciences, Wenzhou Medical University, Ningbo, China. Electronic address:

Severe corneal injuries can cause visual impairment even blindness. Surgically stitching or implanting biomaterials have been developed, but their implementation requires professional surgeons, failing to address the immediate need of medical treatment. The pressing challenge lies in developing multifunctional biomaterials that enable self-management of corneal injuries.

View Article and Find Full Text PDF

Translation and validation of the 8-item contact lens dry eye questionnaire (CLDEQ-8) among Chinese soft contact lens wearers.

Cont Lens Anterior Eye

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China. Electronic address:

Purpose: To develop a Chinese version of the 8-item Contact Lens Dry Eye Questionnaire (CLDEQ-8) with cross-cultural adaption and clinical validation among soft contact lens wearers (SCL) in China.

Methods: The translation and adaptation of the Chinese CLDEQ-8 (C-CLDEQ-8) followed a rigorous methodological process based on cross-cultural research guidelines consisting of three main phases: 1) forward and backward translation of original CLDEQ-8 into Chinese, 2) cross-cultural adaptation performed by medical advising committee, and 3) clinical validation and repeatability test of the translated questionnaire on Chinese SCL wearers. Rasch analysis was also performed to investigate the psychometric properties of C-CLDEQ-8.

View Article and Find Full Text PDF