Introduction: In the Transversus Abdominis Release (TAR) procedure, ideally, the posterior sheath is completely reapproximated to establish an interface isolating the polypropylene mesh from visceral contents. When primary closure of the posterior sheath is unachievable, Vicryl mesh is commonly used to supplement the posterior sheath closure and an uncoated polypropylene mesh is placed superficial to the Vicryl mesh. The long-term implications of utilizing Vicryl mesh as an antiadhesive barrier are poorly understood. In this study, we aimed to assess our outcomes when utilizing Vicryl mesh to supplement the posterior sheath defects when placed underneath polypropylene mesh in patients undergoing posterior component separation.

Methods: Adult patients who underwent VHR with concurrent TAR procedure with a permanent synthetic mesh and posterior sheath supplementation with Vicryl mesh in the Cleveland Clinic Center for Abdominal Core Health between January 2014 and December 2022 were queried retrospectively from a prospectively collected database in the Abdominal Core Health Quality Collaborative. We evaluated 30-day wound morbidity, perioperative complications, long-term mesh-related complications, and pragmatic hernia recurrence.

Results: 53 patients who underwent TAR procedure with posterior sheath supplementation using Vicryl mesh and had a minimum 12-month follow-up were identified. Of the 53 patients, 94.3% presented with recurrent hernias, 73.6% had a midline hernia, 7.5% had a flank hernia, and 18.9% had concurrent parastomal hernia. The mean hernia width was 24.9 cm (± 8.8 cm). No Vicryl mesh-related operative complications were identified in our study, with no instances of mesh erosion, fistulas, or interventions for small bowel obstruction. Skin necrosis requiring reoperations was observed in three patients (5.7%), leading to permanent mesh excision in two cases (3.8%) without intraabdominal visceral involvement. Throughout the 12-month follow-up, 23 incidences (43.4%) of surgical site occurrences (SSOs) and surgical site occurrences requiring procedural intervention (SSOPI) were documented.

Conclusions: Our findings suggest that posterior sheath supplementation with Vicryl mesh is a feasible approach to achieve posterior sheath closure in challenging abdominal wall reconstruction cases. Given the absence of notable mesh-related complications and a similar hernia recurrence rate to cases without posterior sheath supplementation, Vicryl mesh can be used to safely achieve posterior sheath closure in complex reconstructions with insufficient native tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10029-024-03054-4DOI Listing

Publication Analysis

Top Keywords

posterior sheath
44
vicryl mesh
36
sheath supplementation
20
supplementation vicryl
20
mesh
15
tar procedure
12
polypropylene mesh
12
sheath closure
12
sheath
11
posterior
11

Similar Publications

Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.

View Article and Find Full Text PDF

Lifesaving surgical approaches for severe penetrating knife injury to the neck.

J Cardiothorac Surg

January 2025

Institute of Cardiovascular and Thoracic Surgery, Madras Medical College, Chennai, India.

Background: Penetrating neck injuries are rare and require urgent surgical intervention to prevent life-threatening complications. This report highlights a unique case involving complex surgical repair of tracheal, esophageal, and vascular injuries following a homicidal assault, emphasizing the challenges and techniques used in managing such severe trauma.

Case Presentation: A 45-year-old female presented with a severe penetrating neck injury after an alleged homicidal assault with a knife.

View Article and Find Full Text PDF

The anatomy of the sciatic nerve allows it to be blocked at different levels using various anesthetic approaches. However, for several reasons, performing these approaches may be challenging or disadvantageous in specific categories of patients, particularly in obese patients. The objective of this brief technical report is to describe a new technical approach to sciatic nerve block, designed to simplify the procedure for certain categories of patients and less experienced practitioners.

View Article and Find Full Text PDF

The present study describes the differentiation process of male germ cells in Octopus vulgaris, the morphology of sperm in the testis and spermatophore, and the sperm released after the spermatophoric reaction. During spermatogenesis, the male sperm cell gradually elongates from a round shape, with cytoplasm shifting toward the head and the acrosome forming. Additionally, in the spermatid stage, the flagellum develops within the posterior nuclear channel and extends outside the cytoplasm.

View Article and Find Full Text PDF

The perineurioma (PN) is a benign neoplasm with perineural origin. It can be of two types, i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!