Introduction: Robotic-assisted total hip arthroplasty (RA-THA) provides an alternative to fluoroscopic guidance, thus reducing radiation exposure for orthopaedic surgeons. This study was performed to assess the learning curve associated with the adoption of RA-THA using the direct anterior approach (DAA) with regard to surgical time, use of fluoroscopy, and implant placement. In addition, we compared complication rates and patient-reported outcome scores between both cohorts. A case report of an RA-THA is also presented.

Materials And Methods: This was a retrospective, non-randomized evaluation of the learning curve by assessing surgical time on a consecutive series of 89 DAA cases performed by a single surgeon. There were 53 cases that had manual THA with fluoroscopy and 36 cases with RA-THA. All cases had an acetabular component placement target of 40° inclination and 20° anteversion. An independent reviewer blinded to surgical technique used the Widmer method to measure acetabular inclination and version. Patient demographics were similar for both groups.

Results: The mean surgical time for the manual fluoroscopic group was 88 ± 21 minutes and 101 ± 14 minutes for the RA-THA group. After 15 RA-THA cases, surgical time reached time neutral compared to the manual fluoroscopic group. The first 17 RA-THA cases utilized fluoroscopy to verify implant position until the surgeon became comfortable with the accuracy of the RA-THA system. After case 17, fluoroscopy was abandoned in all subsequent RA-THA cases. The mean radiation dose delivered to the surgical field was 5.61 ± 5.71 mGy. Manual THA with fluoroscopy resulted in a mean acetabular inclination of 41.3 ± 4.4° and a mean anteversion of 22.4 ± 3.0°. The RA-THA resulted in a mean acetabular inclination of 42.0 ± 4.2° and a mean anteversion of 22.3 ± 3.9°. There was no noted change in RA-THA placement accuracy after case 17, when fluoroscopy was eliminated from the surgical workflow. There were no statistical differences between the manual fluoroscopic and robotic-assisted groups with respect to complications and clinical PROM outcomes.

Conclusion: The DAA THA can be performed with RA-THA and achieve comparable acetabular placement without fluoroscopy. Surgical time was higher for the RA-THA group during the learning curve, but then decreased and was consistent with the manual fluoroscopic group after 15 cases.

Download full-text PDF

Source
http://dx.doi.org/10.52198/24.STI.44.OS1772DOI Listing

Publication Analysis

Top Keywords

surgical time
20
learning curve
16
ra-tha cases
16
manual fluoroscopic
16
ra-tha
13
acetabular inclination
12
fluoroscopic group
12
fluoroscopic robotic-assisted
8
direct anterior
8
total hip
8

Similar Publications

Circumstantial risk factors for death after intensive care unit-to-unit inter-hospital transfer-a Swedish registry study.

Scand J Trauma Resusc Emerg Med

January 2025

Anaesthesiology and Intensive Care, Department of Surgical Sciences, Uppsala University, 715 85, Uppsala, Sweden.

Background: Unit-to-unit transfer of critically ill patients infers hazards that may cause adverse events. Circumstantial factors associated with mortality after intensive care include days in the ICU, night-time or weekend discharge and capacity transfer as compared to other reasons for transfer. Distance travelled may also constitute an indirect risk.

View Article and Find Full Text PDF

Background: vNOTES has been documented as a viable approach for conducting benign gynecologic surgery; however, its application in ectopic pregnancy cases remains relatively scarce. The principal objective of this investigation was to assess the practicability, effectiveness, and safety of vNOTES in surgical procedures related to ectopic pregnancy.

Methods: Clinical data pertaining to patients diagnosed with ectopic pregnancy at Beijing Hospital between January 2018 and August 2023 were retrospectively collected (This study retrospectively registered with the China Clinical Trial Registry with the registration number ChiCTR2100052223 in September 22, 2021.

View Article and Find Full Text PDF

Background And Objective: There is a significant medical need for improved long-acting local anesthetics to decrease postsurgical pain and reduce postoperative opioid use. While ropivacaine is considered a safer local anesthetic than bupivacaine, no long-acting ropivacaine formulation is currently marketed. Available formulations of bupivacaine show inconsistent pharmacokinetics (PK) among different surgical models, and inconsistency in PK may lead to a reluctance to use the medication owing to fear of local anesthetic systemic toxicity (LAST) or unreliable efficacy.

View Article and Find Full Text PDF

Background: Treatment of ankle osteoarthritis by total ankle replacement (TAR) is increasing worldwide. The aim of the study was to present the overall temporal trends of TAR throughout 22 years (2001-2022) in Italy, analyzing the distributions of hospitals by volume of activity and patients by age and sex, drawing on the National Hospital Discharge Record database. Furthermore, as a secondary aim, we compared these trends with those of ankle fusions.

View Article and Find Full Text PDF

The presence of an aberrant right hepatic artery (a-RHA) could influence the oncological and postoperative outcomes after pancreaticoduodenectomy (PD). A comparative study was conducted, including patients who underwent PD with a-RHA or with normal RHA anatomy. The primary endpoints were R1 resection in all margins (pancreatic, anterior, posterior, superior mesenteric artery, and portal groove), overall survival (OS), and disease-free survival (DFS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!