Objectives: Kidney transplant survival can be improved with better graft surveillance postoperatively. In the quest to explore new technologies, we explored the feasibility of an implantable Doppler probe as a blood flow monitoring device in kidney transplant patients. This qualitative study was embeddedin a feasibility trial and aimed to test the device's clinical acceptability and obtain suggestions for the development of the intervention. Objectives included exploring the experiences of feasibility study participants and identifying barriers to the implementation of implantable Doppler probes in clinical practice.

Materials And Methods: We conducted semi-structured interviews containing open-ended questions with 12 feasibility study participants recruited by purposive sampling. All interviews were audio-recorded with verbatim transcription. Thematic data analysis was performed at the latent level by using an inductive approach with a previously published 6-phase guide.

Results: Three key themes emerged: (1) perceived value of the intervention in clinical practice, (2) challenges and barriers to implementation of the intervention, and (3) suggestions forthe development of the intervention. Due to functional limitations and lack of research, medical professional participants revealed clinical equipoise regarding the utility of implantable Doppler probes. However,the device was well received by patient participants. Challenges included device training needs for medical professionals and educational sessions for patients. Innovative ideas for development included the insertion of a display screen, adopting disposable units to reduce overall cost, online access allowing remote monitoring, decreasing external monitoring unit size, and integrating a wireless connection with the probe to reduce signal errors and increase patient safety.

Conclusions: The clinical need for blood flow sensing technology in kidney transplants has been widely acknowledged. Implantable Doppler probes may be a beneficial adjunct in the early postoperative surveillance of kidney transplant patients. However, the device's technical limitations are the main challenges to its acceptance in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.6002/ect.2023.0273DOI Listing

Publication Analysis

Top Keywords

implantable doppler
20
kidney transplant
12
doppler probes
12
feasibility implantable
8
doppler probe
8
qualitative study
8
blood flow
8
transplant patients
8
development intervention
8
feasibility study
8

Similar Publications

Patients at high risk of deep vein thrombosis are recommended to undergo lower-extremity ultrasonography to screen for pulmonary embolism (PE); however, there are few reports on whether this can effectively reduce the occurrence of fatal pulmonary embolism (FPE). This study aimed to assess the risk factors associated with PE and to investigate whether perioperative ultrasound screening of lower extremity veins in orthopedic patients can effectively reduce the incidence of FPE. We enrolled 137 patients with PE who underwent orthopedic surgery between 2013 and 2020.

View Article and Find Full Text PDF
Article Synopsis
  • Popliteal artery injury is a rare but significant complication of knee arthroscopic surgery, highlighting a need for more research due to a lack of data and guidelines.
  • The study analyzed 17,000 procedures and found a 0.059% incidence of popliteal artery injury among 10 patients, detailing the types of surgeries performed and various treatment methods used.
  • After an average follow-up of over 43 months, patients showed no reported complications and exhibited positive recovery in joint function and vascular health.
View Article and Find Full Text PDF

Background: Gluteal hypoplasia and ptosis reduction are common concerns among patients seeking optimal body contouring in Peru and other countries. Although silicone implants are a traditional solution, they are not suitable for all patients. Fat grafting has emerged as an alternative, with various techniques aimed at enhancing fat graft viability and patient safety.

View Article and Find Full Text PDF

The hemodynamic definitions of pulmonary hypertension consider resistive loading (pulmonary vascular resistance [PVR]), but there are increasing evidence that pulsatile loading (pulmonary artery compliance [PAC]) has functional and prognostic importance. The aims of the present study on patients with left heart disease, were to evaluate a novel echocardiographic right ventricular (RV) afterload score and to investigate its relation to risk of mortality or implantation of a left ventricular assist device. Patients ( = 220) with left ventricular ejection fraction < 50% consecutively referred for heart transplant or heart failure workup underwent echocardiography and right heart catheterization.

View Article and Find Full Text PDF

Acupuncture and traditional Chinese medicine (TCM) have shown certain benefits in assisted in vitro fertilization and embryo transfer (IVF-ET). In this study, we evaluated the efficacy and safety of the combination of acupuncture combined with the Bushen Quyu decoction in patients with failures of IVF-ET. This study was conducted at Shanghai Yangpu District Hospital of TCM from May to November of 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!