Although tension band wiring (TBW) is popular and recommended by the AO group, the high rate of complications such as skin irritation and migration of the K-wires cannot be ignored. Ding's screw tension band wiring (DSTBW) is a new TBW technique that has shown positive results in the treatment of other fracture types. The objective of this study was to evaluate the stability of DSTBW in the treatment of olecranon fractures by biomechanical testing. We conducted a Synbone biomechanical model by using three fixation methods: DSTBW, intramedullary screw and tension band wiring (IM-TBW), and K-wire TBW, were simulated to fix the olecranon fractures. We compared the mechanical stability of DSTBW, IM-TBW, and TBW in the Mayo Type IIA olecranon fracture Synbone model using a single cycle loading to failure protocol or pullout force. During biomechanical testing, the average fracture gap measurements were recorded at varying flexion angles in three different groups: TBW, IM-TBW, and DSTBW. The TBW group exhibited measurements of 0.982 mm, 0.380 mm, 0.613 mm, and 1.285 mm at flexion angles of 0°, 30°, 60°, and 90° respectively. The IM-TBW group displayed average fracture gap measurements of 0.953 mm, 0.366 mm, 0.588 mm, and 1.240 mm at each of the corresponding flexion angles. The DSTBW group showed average fracture gap measurements of 0.933 mm, 0.358 mm, 0.543 mm, and 1.106 mm at the same flexion angles. No specimen failed in each group during the cyclic loading phase. Compared with the IM-TBW and TBW groups, the DSTBW group showed significant differences in 60° and 90° flexion angles. The mean maximum failure load was 1229.1 ± 110.0 N in the DSTBW group, 990.3 ± 40.7 N in the IM-TBW group, and 833.1 ± 68.7 N in the TBW group. There was significant difference between each groups (p < 0.001).The average maximum pullout strength for TBW was measured at 57.6 ± 5.1 N, 480.3 ± 39.5 N for IM-TBW, and 1324.0 ± 43.8 N for DSTBW. The difference between maximum pullout strength of both methods was significant to p < 0.0001. DSTBW fixation provides more stability than IM-TBW and TBW fixation models for olecranon fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11063218PMC
http://dx.doi.org/10.1038/s41598-024-60264-7DOI Listing

Publication Analysis

Top Keywords

flexion angles
20
tension band
16
band wiring
16
olecranon fractures
12
average fracture
12
fracture gap
12
gap measurements
12
dstbw group
12
group
9
treatment olecranon
8

Similar Publications

Purpose: To propose a new sign of patellar maltracking in recurrent patellar dislocation (RPD) and compare the differences in lower limb rotational and bony structural abnormalities among the different signs.

Patients And Methods: A retrospective study included 279 patients (mean age: 22 years; female: 81%) who underwent primary surgery for RPD over the past 4 years was performed. The patients were grouped based on the characteristics of patellar tracking: low-, moderate- and high-grade J-sign.

View Article and Find Full Text PDF

Purpose: Clinicians monitor scoliosis progression using multiple radiographs during growth. During imaging, arms must be elevated to visualize vertebrae, possibly affecting sagittal alignment. This study aimed to determine the arm position that best represents habitual standing (and possibly allowing hand-based skeletal maturity assessment) to obtain frontal and lateral stereo-radiographs as measured using frontal, sagittal, and transverse angles.

View Article and Find Full Text PDF

While the importance of the upper and lower limbs in locomotion is well understood, the kinematics of the trunk during walking remains largely unexplored. Two decades ago, a casual observation was reported indicating spine lengthening in a small sample of mostly children during walking, but this observation was never replicated. Objectives: This study aims to verify the preliminary observation that spine lengthening occurs during walking and to explore changes in spine kinematics across three different age groups.

View Article and Find Full Text PDF

Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation.

View Article and Find Full Text PDF

In order to improve the understanding foot function in the presence of planovalgus foot deformity, functional joint center determination is applied to the ankle and midfoot for application in 3D-gait analysis. Gait data of 36 patients with planovalgus (PV) foot deformity as well as of 33 typically developing (TD) subjects were collected using foot markers according to the Heidelberg Foot Measurement method. During single-limb stance subjects performed a circular movement of the foot and ankle (CIR) by drawing a circle with the hallux in the air.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!