We demonstrate a simple system for dual-comb spectroscopy based on two inherently coherent optical frequency combs generated via seeded parametric downconversion. The inbuilt coherence is established by making the two combs share a common comb line. We show that the inbuilt coherence makes it possible to use a simple numerical post-processing procedure to compensate for small drifts of the dual-comb interferogram arrival time and phase. This enables long-time coherent averaging of the interferograms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.521866 | DOI Listing |
A comparison of the accuracy of intraocular lens (IOL) power calculation formulae, including SRK/T, HofferQ, Holladay 1, Haigis, MM, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and AS-OCT ray tracing, was performed. One hundred eyes implanted with either the Rayone EMV RAO200E (Rayner Intraocular Lenses Limited, Worthing, UK) or the Artis Symbiose (Cristalens Industrie, Lannion, France) IOL were included. Biometry was obtained using IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) and MS-39 AS-OCT (CSO, Firenze, Italy).
View Article and Find Full Text PDFThis publisher's note contains a correction to Opt. Lett.49, 2473 (2024)10.
View Article and Find Full Text PDFRetina
August 2024
Ophthalmology Department, Catholic University "Sacro Cuore", Rome, Italy.
Bioengineering (Basel)
June 2024
Cornea and External Eye Disease Service, Singapore National Eye Center, Singapore 168751, Singapore.
The aim of our study is to investigate the feasibility and outcomes of using a femtosecond laser (FSL) platform (Ziemer LDV Z8) for deep anterior lamellar keratoplasty (DALK), enabling the creation of mushroom-shaped graft-host junctions, lamellar cuts, and intrastromal tunnels, to facilitate the big bubble, in one step. We included wet lab experiments on nine porcine eyes to assess the laser accuracy and cuts depth using an anterior segment (AS) OCT. This was followed by an interventional prospective case series on 10 eyes with variant corneal pathologies.
View Article and Find Full Text PDFWe demonstrate a simple system for dual-comb spectroscopy based on two inherently coherent optical frequency combs generated via seeded parametric downconversion. The inbuilt coherence is established by making the two combs share a common comb line. We show that the inbuilt coherence makes it possible to use a simple numerical post-processing procedure to compensate for small drifts of the dual-comb interferogram arrival time and phase.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!