We demonstrate a simple system for dual-comb spectroscopy based on two inherently coherent optical frequency combs generated via seeded parametric downconversion. The inbuilt coherence is established by making the two combs share a common comb line. We show that the inbuilt coherence makes it possible to use a simple numerical post-processing procedure to compensate for small drifts of the dual-comb interferogram arrival time and phase. This enables long-time coherent averaging of the interferograms.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.521866DOI Listing

Publication Analysis

Top Keywords

inbuilt coherence
12
dual-comb spectroscopy
8
reference-free dual-comb
4
spectroscopy inbuilt
4
coherence demonstrate
4
demonstrate simple
4
simple system
4
system dual-comb
4
spectroscopy based
4
based inherently
4

Similar Publications

A comparison of the accuracy of intraocular lens (IOL) power calculation formulae, including SRK/T, HofferQ, Holladay 1, Haigis, MM, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and AS-OCT ray tracing, was performed. One hundred eyes implanted with either the Rayone EMV RAO200E (Rayner Intraocular Lenses Limited, Worthing, UK) or the Artis Symbiose (Cristalens Industrie, Lannion, France) IOL were included. Biometry was obtained using IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) and MS-39 AS-OCT (CSO, Firenze, Italy).

View Article and Find Full Text PDF
Article Synopsis
  • The study introduces a new visualization method for peeling epiretinal membranes (ERM) using the Alcon Ngenuity 3D System's picture-in-picture feature connected to a smartphone.
  • Conducted on 20 patients, researchers used optical coherence tomography angiography to create detailed en-face images, enabling precise peeling of the ERM without the use of dye stains.
  • Results showed a 100% success rate in the initiation of peeling, with significant improvements in central macular thickness one month post-surgery, highlighting the technique's efficiency and ease of use.
View Article and Find Full Text PDF

The aim of our study is to investigate the feasibility and outcomes of using a femtosecond laser (FSL) platform (Ziemer LDV Z8) for deep anterior lamellar keratoplasty (DALK), enabling the creation of mushroom-shaped graft-host junctions, lamellar cuts, and intrastromal tunnels, to facilitate the big bubble, in one step. We included wet lab experiments on nine porcine eyes to assess the laser accuracy and cuts depth using an anterior segment (AS) OCT. This was followed by an interventional prospective case series on 10 eyes with variant corneal pathologies.

View Article and Find Full Text PDF

We demonstrate a simple system for dual-comb spectroscopy based on two inherently coherent optical frequency combs generated via seeded parametric downconversion. The inbuilt coherence is established by making the two combs share a common comb line. We show that the inbuilt coherence makes it possible to use a simple numerical post-processing procedure to compensate for small drifts of the dual-comb interferogram arrival time and phase.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?