Fused Granular Fabrication Additive Manufacturing (FGF AM) has the capability to create tooling that is lower cost than conventionally manufactured tooling and still has sufficient properties for many applications. A vacuum infusion (VI) mold was printed from fiberglass-acrylonitrile butadiene styrene (ABS) and evaluated for wear and suitability for small VI runs. The mold was designed to accentuate high wear as a "worst case" scenario. The mold was able to produce 10 parts successfully before any noticeable change occurred to the surface finish. By 14 parts, the surface finish had roughened sufficiently that demolding was difficult and resulted in damage to the part. Profilometry measurements showed a 7 × increase in roughness over the run. No significant tool wear or change in geometry was detected. Even longer life would be expected for typical tooling designs since the test mold was deliberately designed to accentuate wear and demolding issues. Based on these results, similar FGF molds are a feasible option for short run VI production for prototyping or low-volume composites manufacturing, possibly at lower cost and quicker turnaround time than machined aluminum molds.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11057564PMC
http://dx.doi.org/10.1089/3dp.2022.0130DOI Listing

Publication Analysis

Top Keywords

vacuum infusion
8
fused granular
8
granular fabrication
8
fabrication additive
8
additive manufacturing
8
lower cost
8
designed accentuate
8
surface finish
8
durability vacuum
4
tooling
4

Similar Publications

Enzyme-powered synthetic colloidal motors hold promising potential for medical applications because of their unique features such as self-propulsion, sub-micrometer size, fuel bioavailability, and structural and functional versatility. However, the key parameters influencing the propulsion efficiency of enzyme-powered colloidal motors still remain unclear. Here, we report the effect of the neck length of urease-powered pentosan flask-like colloidal motors on their kinematic behavior resembling the role of bacterial flagella.

View Article and Find Full Text PDF

The aim of this study was to compare the mechanical properties of carbon-fiber-reinforced polymer (CFRP) composites produced using three popular technologies. The tests were performed on composites produced from prepregs in an autoclave, the next variant is composites produced using the infusion method, and the third variant concerns composites produced using the vacuum-assisted hand lay-up method. For each variant, flat plates with dimensions of 1000 mm × 1000 mm were produced while maintaining similar material properties and fabric arrangement configuration.

View Article and Find Full Text PDF

Preinduction cervical ripening in previous caesarean pregnancy is limited to intracervical Foley catheter. This study is aimed at finding the vaginal birth rates, improvement of Bishop score, and safety of osmotic dilator (Dilapan-S) among women with previous caesarean pregnancy. We conducted this single-group clinical study after the approval of the institute ethics committee, clinical trial registration, and obtaining informed consent.

View Article and Find Full Text PDF

Monitoring of real-time flow and defects in the vacuum-assisted resin infusion (VARI) process can provide important guidelines for full impregnation of dry reinforcement. A weak fiber Bragg grating array was employed to obtain quasi-distributed monitoring results in real-time. Sensitivity testing of different kinds of coated optical fiber sensors (OFs) was carried out first, and the polyacrylate-coated OF showed a greater wavelength-shift response than the polyimide-coated one.

View Article and Find Full Text PDF

Enhancing the flame resistance of fiber-reinforced epoxy resins will broaden its potential applications. However, the inclusion of a flame retardant in epoxy resins with a curing agent shortens the process, posing a challenge for the production of flame-retardant composites. In this work, the process performance of flame-retardant epoxy resins was improved by using deep eutectic solvents (DES) as the curing agent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!