Objectives: Detailed superiority of CAD EYE (Fujifilm, Tokyo, Japan), an artificial intelligence for polyp detection/diagnosis, compared to endoscopists is not well examined. We examined endoscopist's ability using movie sets of colorectal lesions which were detected and diagnosed by CAD EYE accurately.

Methods: Consecutive lesions of ≤10 mm were examined live by CAD EYE from March-June 2022 in our institution. Short unique movie sets of each lesion with and without CAD EYE were recorded simultaneously using two recorders for detection under white light imaging (WLI) and linked color imaging (LCI) and diagnosis under blue laser/light imaging (BLI). Excluding inappropriate movies, 100 lesions detected and diagnosed with CAD EYE accurately were evaluated. Movies without CAD EYE were evaluated first by three trainees and three experts. Subsequently, movies with CAD EYE were examined. The rates of accurate detection and diagnosis were evaluated for both movie sets.

Results: Among 100 lesions (mean size: 4.7±2.6 mm; 67 neoplastic/33 hyperplastic), mean accurate detection rates of movies without or with CAD EYE were 78.7%/96.7% under WLI (p<0.01) and 91.3%/97.3% under LCI (p<0.01) for trainees and 85.3%/99.0% under WLI (p<0.01) and 92.6%/99.3% under LCI (p<0.01) for experts. Mean accurate diagnosis rates of movies without or with CAD EYE for BLI were 85.3%/100% for trainees (p<0.01) and 92.3%/100% for experts (p<0.01), respectively. The significant risk factors of not-detected lesions for trainees were right-sided, hyperplastic, not-reddish, in the corner, halation, and inadequate bowel preparation.

Conclusions: Unique movie sets with and without CAD EYE could suggest it's efficacy for lesion detection/diagnosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11056537PMC
http://dx.doi.org/10.23922/jarc.2023-041DOI Listing

Publication Analysis

Top Keywords

cad eye
36
movie sets
12
movies cad
12
cad
9
eye
9
detailed superiority
8
superiority cad
8
artificial intelligence
8
unique movie
8
lesions detected
8

Similar Publications

Profile and outcomes of retinal artery occlusion: The underrealized need to expedite presentation.

Indian J Ophthalmol

January 2025

Indian Health Outcomes, Public Health, and Economics Research Center, L. V. Prasad Eye Institute, Hyderabad, Telangana, India.

Purpose: To evaluate the clinical profile of retinal artery occlusion (RAO) and impact of presentation on visual outcomes.

Design: A retrospective analysis of case files of 3070 patients with RAO was performed using electronic medical records.

Methods: Demographic data were analyzed using descriptive statistics.

View Article and Find Full Text PDF

Artificial intelligence applications in ophthalmic optical coherence tomography: a 12-year bibliometric analysis.

Int J Ophthalmol

December 2024

Shenzhen Eye Institute, Shenzhen Eye Hospital, Jinan University, Shenzhen 518040, Guangdong Province, China.

Aim: To explore the current application and research frontiers of global ophthalmic optical coherence tomography (OCT) imaging artificial intelligence (AI) research.

Methods: The citation data were downloaded from the Web of Science Core Collection database (WoSCC) to evaluate the articles in application of AI in ophthalmic OCT published from January 1, 2012 to December 31, 2023. This information was analyzed using CiteSpace 6.

View Article and Find Full Text PDF

Diabetic retinopathy, hypertensive retinopathy, glaucoma, and contrast-related eye diseases are well-recognized conditions resulting from high blood pressure, rising blood glucose, and elevated eye pressure. Later-stage symptoms usually include patches of cotton wool, restricted veins in the optic nerve, and buildup of blood in the optic nerve. Severe consequences include damage of the visual nerve, and retinal artery obstruction, and possible blindness may result from these conditions.

View Article and Find Full Text PDF

Interpretable diagnostic system for multiocular diseases based on hybrid meta-heuristic feature selection.

Comput Biol Med

January 2025

Automatic Control Department, Universitat Politècnica de Catalunya-BarcelonaTech, 08034, Barcelona, Spain; Institut de Recerca Sant Joan de Dèu (IRSJD), 08950, Barcelona, Spain.

Age-related Macular Degeneration (AMD), Cataract, Diabetic Retinopathy (DR) and Glaucoma are the four most common ocular conditions that affect a person's vision. Early detection in the asymptomatic stages can alleviate vision loss or slow down the progression of these diseases. However, manual diagnosis is a costly and tedious process, especially in mass screening applications.

View Article and Find Full Text PDF
Article Synopsis
  • Glaucoma is a progressive eye disease that can lead to permanent blindness, and the paper discusses a new automated diagnosis model that helps doctors quickly classify images as either showing glaucoma or being healthy.
  • The model uses an innovative learning technique called fast discrete curvelet transform with wrapping (FDCT-WRP) to extract features from images, combined with principal component and linear discriminant analyses to streamline the data.
  • The proposed classification algorithm, which merges modified pelican optimization with extreme learning machine (MOD-POA+ELM), demonstrated high accuracy rates of 93.25% and 96.75% on two standard datasets, while also employing various Explainable AI methods to ensure transparency in the diagnosis.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!