Objectives: The progressive increase in the use of implantable electronic devices, vascular access for dialysis and the increased life expectancy of patients with congenital heart diseases has led in recent years to a considerable number of right-side infective endocarditis, especially of the tricuspid valve (TV). Although current guidelines recommend TV repair for native tricuspid valve endocarditis (TVE), the percentage of valve replacements remains very high in numerous studies. The aim of our study is to analyse our experience in the treatment of TVE with a reparative approach.
Methods: This case series includes all the patients who underwent surgery for acute or healed infective endocarditis on the native TV, at the Cliniques Universitaires Saint-Luc (Bruxelles, Belgium) between February 2001 and December 2020.
Results: Thirty-one patients were included in the study. Twenty-eight (90.3%) underwent TV repair and 3 (9.7%) had a TV replacement with a mitral homograft. The repair group was divided into 2 subgroups, according to whether a patch was used during surgery or not. Hospital mortality was 33.3% (n = 1) for the replacement group and 7.1% (n = 2) for repair (P = 0.25). Overall survival at 10 years was 75.6% [95% confidence interval (CI): 52-89%]. Further, freedom from reoperation on the TV at 10 years was 59.3% (95% CI: 7.6-89%) vs 93.7% (95% CI: 63-99%) (P = 0.4) for patch repair and no patch use respectively. Freedom from recurrent endocarditis at 10 years was 87% (95% CI: 51-97%).
Conclusions: Considering that TVE is more common in young patients, a repair-oriented approach should be considered as the first choice. In the case of extremely damaged valves, the use of pericardial patch is a valid option. If repair is not feasible, the use of a mitral homograft is an additional useful solution to reduce the prosthetic material.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11096269 | PMC |
http://dx.doi.org/10.1093/icvts/ivae084 | DOI Listing |
JACC Cardiovasc Interv
December 2024
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.
Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.
Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.
Eur Heart J
January 2025
Department of Cardiology, University Medical Center of the Johannes Gutenberg-University Mainz, Langenbeckstr. 1, 55131 Mainz, Germany.
Eur Heart J Cardiovasc Imaging
January 2025
The Department of Cardiovascular Medicine, Mayo Clinic, Rochester MN.
Aims: Pulmonary regurgitation (PR) after reparative intervention for congenital heart disease has been studied extensively. However, the burden, distribution of causes, and outcome of PR in adults is unknown. The study aimed to evaluate the prevalence, types, and outcomes of moderate/severe PR in adults in the community setting.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Surgery, Virginia Tech Carilion School of Medicine, Roanoke, Virginia.
Background: Undergoing an urgent valve surgical procedure to treat patients with tricuspid valve endocarditis carries a high risk of operative morbidity and mortality. Use of a percutaneous vacuum-assisted system to treat tricuspid valve endocarditis is an alternative to surgical procedures.
Methods: This study retrospectively analyzed data from 187 transcatheter vacuum-assisted aspiration procedures performed in 177 patients with tricuspid valve vegetations at 3 different centers between 2017 and April 2022.
Ann Thorac Surg Short Rep
December 2024
Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
Background: The rate of permanent pacemaker implantation after tricuspid valve (TV) operation is thought to be high, with some studies quoting rates of 20% to 30%. We identified the rate of pacemaker implantation after TV operation at a high-volume regional reference center to better characterize the contemporary risk of pacemaker.
Methods: All adult patients without preexisting pacemakers undergoing TV operation from 2011 to 2022 were included.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!