Aims: Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear.
Methods: Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.
Results: A total of 20 patients (23.3%) had complications, with dislocation alone being the most common (8.1%; 7/86). Ten patients (11.6%) required re-revision surgery. Cementing the HXLPE liner (8.0%; 4/50) had a higher incidence of re-revision due to acetabular component liner-related complications than using the original locking mechanism (0%; 0/36; p = 0.082). Fixation using the original locking mechanism was associated with re-revision due to acetabular component loosening (8.3%; 3/36), compared to cementing (0%; 0/50; p = 0.038). Overall estimated mean survival was 19.2 years. There was no significant difference in the re-revision rate between the original locking mechanism (11.1%; 4/36) and cementing (12.0%; 6/50; p = 0.899). Using Kaplan-Meier survival analysis, the revision-free survival of HXLPE fixed with the original locking mechanism and cementing was 94.1% and 93.2%, respectively, at ten years, and 84.7% and 81.3%, respectively, at 20 years (p = 0.840).
Conclusion: The re-revision rate and the revision-free survival following acetabular component liner exchange revision surgery using the HXLPE liner were not influenced by the fixation technique used. Both techniques were associated with good survival at a mean follow-up of 13 years. Careful patient selection is necessary for isolated acetabular component liner exchange revision surgery in order to achieve the best outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1302/0301-620X.106B5.BJJ-2023-0821.R2 | DOI Listing |
J Orthop Surg Res
December 2024
Department of Orthopeadics, the First Medical Centre, Chinese PLA General Hospital, Beijing, China.
Background: This study aimed to report the mid-term functional outcomes of total hip arthroplasty (THA) for the treatment of advanced hip involvement in ankylosing spondylitis (AS) and identify the factors associated with poor hip flexion range of motion (ROM) after THA in patients with AS.
Methods: We retrospectively investigated the mid-term functional outcomes in 313 AS patients (538 hips) who underwent primary THA from 2012 to 2017, with a mean follow-up of 7 years (range, 4-9 years). Postoperative functional outcomes were assessed by hip flexion ROM, Harris hip score (HHS), and the Western Ontario and McMaster Universities Arthritis Index (WOMAC).
Orthop Surg
December 2024
The First Clinical College, Jinan University & Department of Orthopedics, The First Affiliated Hospital, Jinan University, Guangzhou, China.
Objective: Charcot arthropathy is characterized by varying degrees of sensory loss and rapidly progressive joint destruction. Historically, limited studies indicated that Charcot arthropathy of the hip joint may be a contraindication for total hip arthroplasty (THA). Yet, some recent studies have shown that good clinical results and acceptable survival rate.
View Article and Find Full Text PDFJ Arthroplasty
December 2024
Service of Orthopaedics and Traumatology, Department of Surgery, EOC, Lugano, Switzerland; Università della Svizzera Italiana, Faculty of Biomedical Sciences, Lugano, Switzerland.
Background: Accurate component placement plays a critical role in the outcome of total hip arthroplasty (THA). Robotic-assisted THA (R-THA) has emerged as an option to optimize this aspect compared to the conventional manual THA (C-THA). The aim of this meta-analysis was to analyze the studies comparing R-THA and C-THA.
View Article and Find Full Text PDFSICOT J
December 2024
The Hazeley Academy, Emperor Drive, Hazeley, Milton Keynes, MK8 0PT, United Kingdom.
Introduction: Robot-assisted instrumentation during total hip arthroplasty (THA) has the potential to improve acetabular cup positioning. This study aimed to evaluate the precision of robotic-arm-assisted THA (rTHA) and assess whether the system can provide accurate cup positioning comparable to conventional THA (cTHA).
Methods: A single-center prospective cohort study consisting of 151 patients who underwent THA (108 rTHA and 43 cTHA).
J Orthop Case Rep
December 2024
Department of Orthopaedics, Seth GS Medical College and KEM Hospital, Mumbai, Maharashtra, India.
Introduction: Dual mobility (DM) total hip replacement (THR) features an acetabular component with an unconstrained tripolar build which ensures a greater range of motion without provoking any dislocation.We report three cases with extremes of surgical misadventure where we carried out a revision arthroplasty with a DM cup. The causes of the failure of the primary arthroplasty were multifactorial, even individually, and ranged from instability due to component malposition, trochanteric fracture, intrapelvic prosthesis protrusion, etc.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!