Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Coronary artery plaque burden, low attenuation non-calcified plaque (LAP), and pericoronary adipose tissue (PCAT) on coronary CT angiography (CCTA), have been linked to future cardiac events. The purpose of this study was to evaluate intra- and inter reader reproducibility in the quantification of coronary plaque burden and its characteristics using an artificial intelligence-enhanced semi-automated software.
Materials And Methods: A total of 10 women and 6 men, aged 52 (IQR 49-58) underwent CCTA using a Siemens Somatom Force, Somatom Definition AS and Somatom Definition Flash scanners. Two expert readers utilized dedicated semi-automatic software (vascuCAP, Elucid Bioimaging, Wenham, MA) to assess calcified plaque, low attenuation plaque and PCAT. Readers were blinded to all clinical information and repeated their analysis at 6 weeks in random order to minimize recall bias. Data analysis was performed on the right and left coronary arteries. Intra- and inter-reader reproducibility was compared using Pearson correlation coefficient, while absolute values between analyses and readers were compared with paired non-parametric tests. This is a sub-study of the Specialized Center of Research Excellence (SCORE) clinical trial (5U54AG062334).
Results: A total of 64 vessels from 16 patients were analyzed. Intra-reader Pearson correlation coefficients for calcified plaque volume, LAP volume and PCAT volumes were 0.96, 0.99 and 0.92 for reader 1 and 0.94, 0.94 and 0.95 for reader 2, respectively, (all p < 0.0001). Inter-reader Pearson correlation coefficients for calcified plaque volume, LAP and PCAT volumes were 0.92, 0.96 and 0.78, and 0.99, 0.99 and 0.93 on the second analyses, all had a p value <0.0001. There was no significant bias on the corresponding Bland-Altman analyses.
Conclusion: Volume measurement of coronary plaque burden and PCAT volume can be performed with high intra- and inter-reader agreement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146670 | PMC |
http://dx.doi.org/10.1016/j.cpcardiol.2024.102585 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!