A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Psychometric validation of the hyperglycaemia avoidance scale UK (HAS-UK). | LitMetric

Aims: Hyperglycaemia aversion in type 1 diabetes can be associated with severe hypoglycaemia and impaired awareness of hypoglycaemia but is not routinely assessed clinically. This study aimed to undertake the first psychometric validation of the UK version of the Hyperglycaemia Avoidance Scale (HAS-UK).

Methods: The HAS-UK was completed by adults with type 1 diabetes in three separate research studies. Psychometric properties were evaluated, using exploratory factor analysis, internal consistency, and convergent validity.

Results: Of the 431 participants who completed the HAS-UK in the three studies, mean age was 49.5 years, and 58.0% were women. Mean duration of diabetes was 29 years, with 192 (44.5%) using multiple daily injections and 229 (53.1%) using an insulin pump. Five participants were excluded from analyses due to incomplete HAS-UK responses. Exploratory factor analysis revealed a 3-factor solution, with acceptable internal consistency for 'worry' and 'blood glucose decisions' factors. HAS-UK total score was higher in those using insulin pumps versus multiple daily injections, and 'blood glucose decisions' score was higher in those using a continuous blood glucose sensor versus a meter.

Conclusions: The HAS-UK is a reliable measure with acceptable structural validity and is likely to be useful for evaluating hyperglycaemia aversion in people with type 1 diabetes. Future research would benefit from investigating further psychometric properties including test-retest reliability, sensitivity to change, and clinical significance of scores.

Download full-text PDF

Source
http://dx.doi.org/10.1111/dme.15342DOI Listing

Publication Analysis

Top Keywords

type diabetes
12
psychometric validation
8
hyperglycaemia avoidance
8
avoidance scale
8
hyperglycaemia aversion
8
psychometric properties
8
exploratory factor
8
factor analysis
8
internal consistency
8
multiple daily
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!