Background: The use of dental implants in the treatment of edentulous patients is increasing. Zirconia implants are an alternative to titanium implants, offering advantages in terms of aesthetics and biological compatibility. However, the number of artifacts observed on radiographic images with zirconia implants compared to titanium implants is yet to be determined.

Objectives: The purpose of this study was to evaluate the impact of different cone-beam computed tomography (CBCT) parameters on the production of artifacts in zirconia and titanium implants.

Material And Methods: A dry human mandible was coated with wax to simulate human soft tissues and examined. Subsequently, titanium and zirconia implants were placed at the same points in the posterior region of the mandible. The production of artifacts on CBCT scans was evaluated using 2 parameters. The first parameter, the standard deviation within the region of interest (SDROI), is based on a comparison of the gray levels at implant and control areas. The second parameter was the contrast-to-noise ratio (CNR), which was evaluated for different protocols created by various combinations of the field of view (FOV) area, milliampere [mA] intensity and metal artifact reduction (MAR) programs.

Results: The study found that zirconia implants produced more artifacts than titanium implants. However, the production of artifacts in zirconia implants could be significantly reduced by increasing the mA values, performing CBCT scans with smaller FOV areas, and enabling MAR programs.

Conclusions: The production of artifacts is a disadvantage of zirconia implants, but this drawback can be mitigated by selecting appropriate protocols for the CBCT device.

Download full-text PDF

Source
http://dx.doi.org/10.17219/dmp/157233DOI Listing

Publication Analysis

Top Keywords

zirconia implants
24
production artifacts
16
titanium implants
12
implants
11
computed tomography
8
zirconia
8
titanium zirconia
8
dental implants
8
artifacts zirconia
8
cbct scans
8

Similar Publications

In the present in vitro study, we evaluated the adhesion of an injectable platelet-rich fibrin (i-PRF) to laser-textured zirconia surfaces and their resultant friction behavior against bone tissue. Three types of zirconia surfaces were compared regarding the i-PRF coating effects: 1) grit blasted with 250-μm spherical alumina particles and acid etched with 20% hydrofluoric acid (ZLA), 2) laser textured with a random (RD) surface pattern, or 3) laser textured with a designed pattern based on 16 lines and 8 passages (L16N8). The coefficient of friction (COF) of the specimens was assessed on a reciprocating sliding pin-on-plate tribometer at 1-N normal load, 1 Hz, and a 2-mm stroke length.

View Article and Find Full Text PDF

Background/purpose: Osseointegration potential is greatly depended on the interaction between bone cells and dental implant surface. Since zirconia ceramic has a bioinert surface, functionalization of the surface with an organic compound allylamine was conducted to overcome its drawback of minimal interaction with the surrounding bone.

Materials And Methods: The zirconia surface was initially treated with argon glow discharge plasma (GDP), then combined with amine plasma at three different conditions of 50-W, 75-W and 85-W, to prepare the final samples.

View Article and Find Full Text PDF

Five-Year Results of One-Piece Zirconia Oral Implants Supporting Three-Unit Fixed Dental Prostheses.

Clin Oral Implants Res

January 2025

Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one-piece zirconia implants fabricated from 3Y-TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three-unit fixed dental prostheses (FDP) after five years in function.

Materials And Methods: Twenty-seven patients received a total of 54 implants in a one-stage surgery with immediate provisionalization.

View Article and Find Full Text PDF

Objectives: The aim of this randomised controlled trial was to assess clinical, radiographic and patient reported outcomes of narrow versus standard diameter titanium zirconium (TiZr) implants supporting single crown restorations in posterior sites with limited bone width.

Materials And Methods: Participants requiring replacement of single missing posterior teeth with implant-supported crowns were randomly allocated into 2 treatment groups: narrow (3.3 mm) or standard (4.

View Article and Find Full Text PDF

Multi-Scale Characterisation and Mechanical Adhesion in PVD-Deposited Ca-SZ Coating for Implantable Medical Devices.

Biomedicines

December 2024

Jean Lamour Institute, Department of Micro and Nanomechanics for Life, University of Lorraine, UMR 7198, 54011 Nancy, France.

Oral implantology faces a multitude of technical challenges in light of current clinical experience, underlining the need for innovation in implantable medical devices in both mechanical and biological terms. This study explores the influence of the thickness factor of calcium-doped zirconia (Ca-SZ) coatings deposited by PVD on their intrinsic mechanical properties and the determinism of the latter on adhesion to the TA6V alloy substrate after mechanical loading for applications in dental implantology. Three separate thicknesses of 250 nm, 450 nm and 850 nm were evaluated in terms of mechanical strength, modulus of elasticity and adhesion to the substrate, in accordance with ISO 20502:2005.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!