Immunoassays have been the preferred method for steroid hormone analysis for more than 50 years. Automated immunoassays (AIAs) offer high throughput, rapid data turnaround, and low cost for measuring steroid hormone concentrations. The application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for steroid quantification provides greater specificity and selectivity for individual steroids, the ability to simultaneously analyze multiple steroids, and high throughput and automation. We compared AIA and LC-MS/MS for analysis of 17beta-estradiol (E2) and progesterone (P4) over the course of several menstrual cycles in 12 rhesus macaques (Macaca mulatta). Serum samples were collected every 4 days across four menstrual cycles from each monkey. AIAs were performed on a Roche cobas e411 analyzer. LC-MS/MS analysis was performed on a Shimadzu-Nexera-LCMS-8060 instrument. Scatter plots with Passing-Bablok regression showed excellent agreement between AIA and LC-MS/MS for both E2 and P4. Bland-Altman plots revealed no bias for either method; however, AIA overestimated E2 at concentrations >140 pg/ml and underestimated P4 at concentrations >4 ng/ml compared to LC-MS/MS. A comparison of testosterone concentrations measured by AIA and LC-MS/MS in the same samples was also performed. In contrast to E2 and P4, AIA and LC-MS/MS yielded significantly different results for testosterone concentrations, with AIA consistently underestimating concentrations relative to those obtained by LC-MS/MS. Well-characterized automated immunoassays are an excellent tool for daily monitoring of monkey menstrual cycles or providing single data points requiring fast turnaround. In certain situations where AIAs may provide inaccurate estimations of E2 and P4 concentrations, LC-MS/MS assays are preferable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11327312PMC
http://dx.doi.org/10.1093/biolre/ioae063DOI Listing

Publication Analysis

Top Keywords

aia lc-ms/ms
16
menstrual cycles
12
lc-ms/ms
9
concentrations
8
hormone concentrations
8
steroid hormone
8
automated immunoassays
8
high throughput
8
lc-ms/ms analysis
8
testosterone concentrations
8

Similar Publications

Immunoassays have been the preferred method for steroid hormone analysis for more than 50 years. Automated immunoassays (AIAs) offer high throughput, rapid data turnaround, and low cost for measuring steroid hormone concentrations. The application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for steroid quantification provides greater specificity and selectivity for individual steroids, the ability to simultaneously analyze multiple steroids, and high throughput and automation.

View Article and Find Full Text PDF

Tanshinone IIA inhibits osteoclastogenesis in rheumatoid arthritis via LDHC-regulated ROS generation.

Chin Med

May 2023

Department of Rheumatology, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, Beijing, 100053, China.

Rheumatoid arthritis (RA) is characterized by bone destruction in the afflicted joints, and during the process of bone destruction, osteoclasts play a crucial role. Tanshinone IIA (Tan IIA) has shown anti-inflammatory effects in RA. However, the exact molecular mechanisms by which it delays bone destruction remain largely unexplained.

View Article and Find Full Text PDF

AZD7442 (tixagevimab [AZD8895]/cilgavimab [AZD1061]) is a monoclonal antibody (mAb) combination in development for the prevention and treatment of coronavirus disease 2019. Traditionally, bioanalysis of mAbs is performed using ligand binding assays (LBAs), which offer sensitivity, robustness, and ease of implementation. However, LBAs frequently require generation of critical reagents that typically take several months.

View Article and Find Full Text PDF

Objectives: Testosterone testing is relevant for evaluating castration adequacy and diagnosis of castration-resistant prostate cancer (PCa). However, the recommended testosterone cut-off of 1.7 nmol/L (50 ng/dL) to define adequate castration is based on consensus and not validated for the automated immunoassays (AIA) used in today's medical laboratories.

View Article and Find Full Text PDF

A high-throughput mass spectrometry-based assay for large-scale profiling of circulating human apolipoproteins.

J Lipid Res

July 2020

NUN, INRA, CHU Nantes, UMR 1280, PhAN, IMAD, CRNH-O, Nantes, France; CRNH-O Mass Spectrometry Core Facility, Nantes, France.

Apolipoproteins govern lipoprotein metabolism and are promising biomarkers of metabolic and cardiovascular diseases. Unlike immunoassays, MS enables the quantification and phenotyping of multiple apolipoproteins. Hence, here, we aimed to develop a LC-MS/MS assay that can simultaneously quantitate 18 human apolipoproteins [A-I, A-II, A-IV, A-V, B48, B100, C-I, C-II, C-III, C-IV, D, E, F, H, J, L1, M, and (a)] and determined apoE, apoL1, and apo(a) phenotypes in human plasma and serum samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!