A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Exercise capacity prior to major cancer surgery: A cross-sectional observational study of the validity of the 6-minute walk and 30-second sit-to-stand tests. | LitMetric

Introduction: Cardiopulmonary exercise testing (CPET) is the gold standard for measuring exercise capacity, however, it is resource intensive and has limited availability. This study aimed to determine: 1) the association between the 6-min walk test (6MWT) and the 30-s sit-to-stand test (30STS) with CPET peak oxygen uptake (VO) and anaerobic threshold (AT) and 2) 6MWT and 30STS cut points associated with a higher risk of postoperative complications.

Methods: A cross-sectional study, retrospectively analyzing data collected from a tertiary cancer center over a 23-month period. Measures included CPET VO and AT, 6MWT and 30STS test. Correlations were used to characterize relationships between variables. Receiver operating characteristic curve analyses determined 6MWT and 30STS cut points that aligned with CPET variable cut points.

Results: Note that, 156 participants were included. The 6MWT and 30STS displayed moderate correlations with VO, rho = 0.65, p = 0.01 and rho = 0.52, p < 0.005 respectively. Fair correlations were observed between AT and 6MWT (rho = 0.36, p = 0.01) and 30STS (rho = 0.41, p < 0.005). The optimal cut points to identify VO< 15 mL/kg/min were 493.5 m on the 6MWT and 12.5 stands on the 30STS test and for AT < 11 mL/kg/min were 506.5 m on the 6MWT and 12.5 stands on the 30STS test.

Conclusion: Both the 6MWT and 30STS test could be used as alternative tools for measuring exercise capacity preoperatively in the cancer setting where CPET is not available. A range of 6MWT and 30STS cut points, according to sensitivity and specificity levels, may be used to evaluate risk of postoperative outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ajco.14069DOI Listing

Publication Analysis

Top Keywords

6mwt 30sts
16
exercise capacity
8
30sts cut
8
cut points
8
6mwt
5
30sts
5
capacity prior
4
prior major
4
major cancer
4
cancer surgery
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!