Background: Evaluation of sufficient adenosine response constitutes a significant challenge in myocardial perfusion imaging (MPI). Splenic switch-off in MPI studies denotes a visually (qualitatively) reduced splenic radiotracer signal during adenosine stress and is considered indicative of sufficient cardiac vasodilation. In this study, we examined semi-quantitative and quantitative approaches to splenic switch-off assessment using [O]HO-PET with either summed activity images or calculated parametric splenic blood flow images.
Methods: Cohort 1: 90 clinical patients undergoing [O]HO MPI in whom adenosine response was considered clinically adequate were identified to characterize the corresponding splenic switch-off. Spleen stress/rest-ratio (SSR-ratio) was calculated as spleen stress signal intensity/spleen rest signal intensity on both summed activity and parametric blood flow images. Cohort 2: Twenty-five patients with repeat MPI due to suspected insufficient adenosine response were identified to observe if splenic switch-off on the initial MPI could predict the outcome of the repeat MPI. Cohort 3: Fifty-four patients who were considered adenosine responders on MPI and who had a coronary angiogram (CAG) follow-up within 3 months after MPI served as a separate validation group.
Results: Splenic switch-off was present in most patients with a clinically sufficient adenosine response (Cohort 1), illustrated by both visual (74.4%-86.7%), semi-quantitative (summed activity images) (85.6%), and quantitative (parametric blood flow images) (92.2%) evaluation, which corresponds to the distribution in patients with sufficient adenosine response and follow-up CAG (Cohort 3). In patients suspected of insufficient adenosine response on the initial MPI (Cohort 2), the repeat MPI only yielded different myocardial blood flow (MBF) results if the initial SSR-ratio was >0.90 on splenic parametric blood flow images.
Conclusion: quantitative splenic switch-off assessment on parametric blood flow images was superior to the semi-quantitative splenic switch-off approach. Patients with a suspected insufficient initial adenosine response and SSR-ratio >0.90 can benefit from a repeat MPI. Thus, the integration of quantitative splenic switch-off using parametric blood flow images in the evaluation of adenosine response may support future clinical decision-making.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.nuclcard.2024.101868 | DOI Listing |
J Nucl Cardiol
November 2024
Department of Medicine (Cardiology), Mount Sinai Morningside Hospital, Zena and Michael A. Weiner Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, USA; Department of Population Health Science and Policy, Blavatnik Family Women's Health Research Institute, Icahn School of Medicine at Mount Sinai, New York, USA. Electronic address:
J Cardiol
July 2024
Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan.
Background: Heart transplantation (HTx) is a definitive therapy for refractory heart failure. Cardiac allograft vasculopathy (CAV), characterized by diffuse arteriopathy involving the epicardial coronary arteries and microvasculature, is the major cause of death for patients with HTx. N-ammonia positron emission tomography (NH-PET) can offer diagnostic and prognostic utility for CAV.
View Article and Find Full Text PDFJ Nucl Cardiol
August 2024
Department of Nuclear Medicine and PET-Centre, Aarhus University Hospital, Denmark; Department of Clinical Medicine, Aarhus University, Denmark.
Background: Evaluation of sufficient adenosine response constitutes a significant challenge in myocardial perfusion imaging (MPI). Splenic switch-off in MPI studies denotes a visually (qualitatively) reduced splenic radiotracer signal during adenosine stress and is considered indicative of sufficient cardiac vasodilation. In this study, we examined semi-quantitative and quantitative approaches to splenic switch-off assessment using [O]HO-PET with either summed activity images or calculated parametric splenic blood flow images.
View Article and Find Full Text PDFJ Nucl Cardiol
June 2024
Department of Medicine (Cardiology), Mount Sinai Morningside Hospital, Zena and Michael A. Weiner Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, USA; Department of Population Health Science and Policy, Blavatnik Family Women's Health Research Institute, Icahn School of Medicine at Mount Sinai, New York, USA. Electronic address:
Myocardial perfusion imaging (MPI) is a powerful tool for the functional assessment of ischemia in patients with suspected or known coronary artery disease (CAD). Given that the diagnostic accuracy and prognostic value of MPI and post-test management are highly dependent on achieving an adequate stress vasodilatory response, it is critical to identify those who may not have adequately responded to vasodilator pharmacological stress agents such as adenosine, dipyridamole, and regadenoson. Caffeine, a potent inhibitor of the adenosine receptor, is a compound that can affect vasodilatory hemodynamics, result in false negative studies, and potentially alter management in cases of inaccurate test results.