AI Article Synopsis

  • Odontoid fractures, especially common in the elderly, lead to serious health risks, and surgical treatment shows better outcomes than non-surgical methods.
  • This study investigates the stability of Type II odontoid fractures after certain surgical fixations (Magerl and Harms) using a biomechanical approach with cadaver specimens.
  • Results indicate both fixation techniques maintain similar movement patterns in the cervical spine during various types of motion, with no significant differences in stability or movement dynamics between the two methods.

Article Abstract

Background Context: Odontoid fractures are among the most common cervical spine fractures in the elderly and are associated with increased morbidity and mortality. Clinical evidence suggests improved survival and quality of life after operative intervention compared to nonoperative treatment.

Purpose: This study seeks to examine the stability of an osteoporotic Type II odontoid fracture following posterior atlantoaxial fixation with either the Magerl transarticular fixation technique or the Harms C1 lateral mass screws C2 pedicle screw rod fixation.

Study Design: Biomechanical cadaveric study.

Methods: Eighteen cadaveric specimens extending from the cephalus to C7 were used in this study. Reflective marker arrays were attached to C1 and C2 and a single marker on the dens to measure movement of each during loading with C2-C3 and occiput-C1 being allowed to move freely. A biomechanical testing protocol imparted moments in flexion-extension, axial rotation, and lateral bending while a motion capture system recorded the motions of C1, C2, and the dens. The spines were instrumented with either the Harms fixation (n=9) or Magerl fixation (n=9) techniques, and a simulated Type II odontoid fracture was created. Motions of each instrumented spine were recorded for all moments, and then again after the instrumentation was removed to model the injured, noninstrumented state.

Results: Both Harms and Magerl posterior C1-C2 fixation allowed for C1, C2, and the dens to move as a relative unit. Without fixation the dens motion was coupled with C1. No significant differences were found in X, Y, Z translation motion of the dens, C1 or C2 during neutral zone motions between the Magerl and Harms fixation techniques. There were no significant differences found in Euler angle motion between the two techniques in either flexion-extension, axial rotation, or lateral bending motion.

Conclusions: Our findings suggest that both Harms and Magerl fixation can significantly reduce dens motion in Type II odontoid fractures in an osteoporotic cadaveric bone model.

Clinical Significance: Both Harms and Magerl posterior atlantoaxial fixation techniques allowed for C1, C2, and the dens to move as a relative unit following odontoid fracture, establishing more anatomic stability to the upper cervical spine.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2024.04.017DOI Listing

Publication Analysis

Top Keywords

odontoid fracture
16
posterior atlantoaxial
12
atlantoaxial fixation
12
type odontoid
12
harms magerl
12
fixation
10
odontoid fractures
8
cervical spine
8
flexion-extension axial
8
axial rotation
8

Similar Publications

Evaluation of postoperative drainage necessity in posterior atlantoaxial fixation via intermuscular approach for odontoid fracture.

Sci Rep

January 2025

Department of Orthopedics, Shanghai Changzheng Hospital, Naval Medical University, 415 Fengyang Road, Huangpu District, Shanghai, 200003, People's Republic of China.

The necessity of routinely placing closed suction wound drainage in spinal surgery has been questioned. This study aims to assess if closed suction wound drainage is necessary for posterior atlantoaxial fixation via intermuscular approach. The functional outcomes of these 40 patients who underwent posterior atlantoaxial fixation via intermuscular approach without drainage tube (Group A) were compared with that of a control group, which consisted of 68 randomly enrolled cases with posterior atlantoaxial fixation via intermuscular approach with drainage tube (Group B).

View Article and Find Full Text PDF

Atalanto-occipital dislocations with type II fractures of the odontoid process are rare, reporting 7 cases for every 784 upper cervical spine injuries, an incidence of <0.3% and are related to a high rate of morbidity and mortality. Regarding C2 fractures, the most common are in the odontoid process, representing 7%, classified by Anderson and D'Alonso according to their level, with the highest rate of pseudarthrosis in zone II of up to 85% are caused mainly by car accidents.

View Article and Find Full Text PDF

Background: The Da Vinci robot ® (DVR), released in the early 2000s, provided a set of innovation aiming at pushing minimally invasive surgery forward. Its stereoscopic magnified visualization camera, motions that exceed the natural range of the human hand, or tremor reduction enhanced the surgeon's skills and added value in many surgical fields.

Objective: To map the current use of the DVR in spine surgery, identify gaps, address its limits and future perspectives.

View Article and Find Full Text PDF

Instrumentation of the cervical spine particularly at the higher cervical levels like C2 presents unique challenges mainly because of their complex anatomy and proximity to neurovascular structures. The goal of the article is to demonstrate that using navigation technologies in inserting anterior odontoid screws can enhance the precision and safety of surgery. We describe a novel approach for anterior C2 odontoid fixation using a three-pin radiolucent Mayfield clamp with intra-operative CT registration and cranial brainlab navigation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!