Purpose: To provide lumbar spine anatomical parameters relevant to the UBE technique and explore their intraoperative application.
Methods: CT imaging data processed by Mimics for parametric measurements, including laminar abduction angle (LAA), laminar slope angle (LSA), minimum laminar height (MLH), distance between the inferior margin of the lamina and attachment of the ligamentum flavum onto the cephalad lamina (DLL), distance between the initial point and the middle of the articular process (DIA), and distance from the inferior margin of the lamina to the inferior border of the vertebral body (DLV), and were manually measured.
Results: LAA and DIA gradually increase from L1 to L5. At L1, the DIA is approximately the length of 2 drill bits with a diameter of 3 mm (male: 7.77 ± 1.39 mm, female: 7.22 ± 1.09 mm), while at L5, it can reach the length of 4-5 drill bits (male: 14.96 ± 2.24 mm, female: 13.67 ± 2.33 mm). MLH, DLL, and DLV reach their maximum values at the L3 and decrease toward the cranial and caudal ends. The DLL is smallest at L5 (male: 9.58 ± 1.90 mm, female: 9.38 ± 2.14 mm), equivalent to the length of 3 drill bits, while the DLL at L3 is the length of 4-5 drill bits (male: 14.17 ± 2.13 mm, female: 14.01 ± 2.07 mm).
Conclusion: Referring to the drill diameter during surgery can mark the extent of laminotomy. The characteristics of vertebral plate angles at different lumbar levels can provide references for preoperative incision design.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00586-024-08270-1 | DOI Listing |
Am J Vet Res
January 2025
Department of Surgical and Radiological Sciences, University of California-Davis, Davis, CA.
Objective: Histologically evaluate damage to rabbit femur after the creation of bicortical 1.5-mm-diameter holes using a standard surgical drill bit, an acrylic drill bit, and a Kirschner wire (K-wire).
Methods: 10 femora (5 pairs) from skeletally mature female intact New Zealand white rabbits were used.
Sci Rep
October 2024
Xi'an Keyuan Municipal Engineering Consulting Co, Xi an, 710000, China.
Bioengineering (Basel)
September 2024
School of Engineering, Stony Brook University, Stony Brook, NY 11794, USA.
Sequential drilling is a common practice in dental implant surgery aimed at minimizing thermal damage to bone. This study evaluates the thermal effects of sequential drilling and assesses modifications to drilling protocols to manage heat generation. We utilized a custom drill press and artificial bone models to test five drill bits under various protocols, including sequential drilling with different loads, spindle speeds, and peck drilling.
View Article and Find Full Text PDFHeliyon
September 2024
Faculty of Mechanical Engineering Technology, Universiti Malaysia Perlis, 02600, Arau, Perlis, Malaysia.
Drilling is a widely employed technique in machining processes, crucial for efficient material removal. However, when applied to living tissues, its invasiveness must be carefully considered. This study investigates drilling processes on polyurethane foam blocks mimicking human bone mechanical properties.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!