Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: 6-Bromo-7-[C]methylpurine ([C]BMP) is a radiotracer for positron emission tomography (PET) to measure multidrug resistance-associated protein 1 (MRP1) transport activity in different tissues. Previously reported radiosyntheses of [C]BMP afforded a mixture of 7- and 9-[C]methyl regioisomers. To prepare for clinical use, we here report an improved regioselective radiosynthesis of [C]BMP, the results of a non-clinical toxicity study as well as human dosimetry estimates based on mouse PET data.
Results: [C]BMP was synthesised by regioselective N-methylation of 6-bromo-7H-purine (prepared under good manufacturing practice) with [C]methyl triflate in presence of 2,2,6,6-tetramethylpiperidine magnesium chloride in a TRACERlab™ FX2 C synthesis module. [C]BMP was obtained within a total synthesis time of approximately 43 min in a decay-corrected radiochemical yield of 20.5 ± 5.2%, based on starting [C]methyl iodide, with a radiochemical purity > 99% and a molar activity at end of synthesis of 197 ± 130 GBq/μmol (n = 28). An extended single-dose toxicity study conducted in male and female Wistar rats under good laboratory practice after single intravenous (i.v.) administration of unlabelled BMP (2 mg/kg body weight) revealed no test item related adverse effects. Human dosimetry estimates, based on dynamic whole-body PET data in female C57BL/6J mice, suggested that an i.v. injected activity amount of 400 MBq of [C]BMP will deliver an effective dose in the typical range of C-labelled radiotracers.
Conclusions: [C]BMP can be produced in sufficient amounts and acceptable quality for clinical use. Data from the non-clinical safety evaluation showed no adverse effects and suggested that the administration of [C]BMP will be safe and well tolerated in humans.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058743 | PMC |
http://dx.doi.org/10.1186/s41181-024-00265-z | DOI Listing |