A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of biotin on currently used Beckman thyroglobulin assay and newly reformulated thyroglobulin assay not affected by biotin. | LitMetric

Objectives: Biotin causes negative interference with thyroglobulin measurement using the Access thyroglobulin assay. Recently, Beckman reformulated the thyroglobulin assay to overcome biotin interference. We investigated the effect of biotin on both current and newly formulated assays.

Methods: Four serum pools were prepared using specimens containing various amounts of thyroglobulin. Then aliquots of each pool were supplemented with various amounts of biotin, and thyroglobulin concentrations were measured by both the current and the new assays. In addition, 3 volunteers ingested 10 mg biotin, and specimens were drawn before and 2 hours after taking biotin. Thyroglobulin concentrations before and 2 hours after taking biotin were measured by both assays.

Results: In the presence of biotin, thyroglobulin concentrations were reduced significantly using the current assay, but no significant change was observed using the newly formulated assay. We observed similar results in vivo.

Conclusions: The newly formulated thyroglobulin assay by Beckman is free from biotin interference.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ajcp/aqae048DOI Listing

Publication Analysis

Top Keywords

thyroglobulin assay
20
newly formulated
12
biotin thyroglobulin
12
thyroglobulin concentrations
12
biotin
11
thyroglobulin
10
reformulated thyroglobulin
8
assay beckman
8
biotin interference
8
hours biotin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!