A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In-situ acetylation followed by liquid-liquid extraction and gas chromatography - mass spectrometry for the determination of bromophenols in urine. | LitMetric

In-situ acetylation followed by liquid-liquid extraction and gas chromatography - mass spectrometry for the determination of bromophenols in urine.

Talanta

Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemical Sciences, 37008, Salamanca, Spain.

Published: August 2024

A novel and simple method combining in-situ acetylation, liquid-liquid extraction and gas chromatography-mass spectrometry (GC-MS) has been developed for the quantification of 10 bromophenols in urine, used as biomarkers of exposure to polybrominated diphenyl ethers. The analytical process involves an enzymatic hydrolysis of the bromophenol glucuronide fraction followed by an aqueous derivatization of the phenol group with acetic anhydride. A subsequent liquid-liquid extraction of the sample with hexane allows the injection of the organic layer, using a programmed temperature vaporizer, into a gas chromatograph coupled to a single quadrupole mass spectrometer. Quantification is performed by the standard addition method. Limits of detection are in the pg mL range. Trueness, assessed in terms of percentages of recovery, varies between 100 % and 118 % in synthetic urine and between 79 % and 117 % in human urine. Precision, assessed at two different levels, 0.25 ng mL and 2.5 ng mL, shows values of relative standard deviation below 14 % both in intra- and inter-day studies for both matrices. The method has been applied to the analysis of seven urine samples, measuring concentrations higher than the LOQ in three of them. These levels are in agreement with others found in literature, but they have been obtained by applying a much simpler and faster protocol. In addition, the replacement of silylating reagents by acetic anhydride, to derivatize the phenol moiety, provides a greener alternative to other GC-MS procedures published up to date.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.126146DOI Listing

Publication Analysis

Top Keywords

liquid-liquid extraction
12
in-situ acetylation
8
acetylation liquid-liquid
8
extraction gas
8
bromophenols urine
8
acetic anhydride
8
urine
5
gas chromatography
4
chromatography mass
4
mass spectrometry
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!