Background: It is unclear whether salivary iodine concentration (SIC) can assess iodine status in females from different water iodine regions.
Objectives: Through a cross-sectional study, we explored the feasibility of SIC as a biomarker to assess iodine status in females and develop optimal cutoff values.
Methods: A total of 1991 females were analyzed in this cross-sectional study from the coastal iodine-deficient areas (CIDAs), inland iodine-deficient areas (IIDAs), iodine-adequate areas (IAAs), iodine-excess areas (IEAs), and iodine extra-high areas (IEHAs). SIC, spot urine iodine concentration (SUIC), and daily total iodine intake (TII) were assessed, and ultrasonography was performed in all subjects.
Results: There was a positive correlation between SIC and SUIC (r = 0.67; 95% CI: 0.64, 0.69; P < 0.001), and TII (r = 0.47; 95% CI: 0.43, 0.50; P < 0.001). The prevalence of thyroid nodules (TN) showed an upward trend with SIC increasing (Z = -2.83; P-trend = 0.005). The area under the receiver-operating characteristic (ROC) curve for SIC to assess iodine deficiency was 0.62 (95% CI: 0.60, 0.65; P < 0.001) and 0.75 (95% CI: 0.73, 0.77; P < 0.001) for iodine excess. The cutoff values were as follows: SIC < 93.32 μg/L, iodine deficiency; 93.32-224.60 μg/L, iodine adequacy; and >224.60 μg/L, iodine excess. When SIC > 224.60 μg/L, the odds ratio (OR) for UIC > 300 μg/L, excessive TII, and the prevalence of TN were 6.44, 3.68, and 1.27 (95% CI: 4.98, 8.31; 2.83, 4.79; and 1.02, 1.56, respectively; P < 0.05); when SIC < 93.32 μg/L, the OR for UIC < 100 μg/L and insufficient TII were 2.34 and 1.94 (95% CI: 1.73, 3.14 and 1.33, 2.83, respectively; P < 0.05).
Conclusions: Using SIC as a biomarker, females in CIDA exhibited mild iodine deficiency, those in IIDA and IAA demonstrated moderate iodine deficiency, and those in IEA and IEHA exhibited an excess of iodine, consistent with SUIC to assess iodine status. SIC can be used as a good biomarker to evaluate the iodine status in population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ajcnut.2024.04.023 | DOI Listing |
Water Sci Technol
January 2025
Qingdao Branch of Luoyang Ship Material Research Institute, 149-1, Zhuzhou Road, Laoshan District, Qingdao, Shandong, China; Sunrui Marine Environment Engineering Co., Ltd, Qingdao, Shandong, China.
Nowadays, performance studies on the amperometric total residual oxidant (TRO) sensor are only in the bench test stage and have not been conducted under specific maritime conditions with Ballast Water Management System (BWMS). In this study, the application of the amperometric TRO sensor in land-based biological efficacy (BE) testing, operation and maintenance (O&M) testing, as well as shipboard (SB) testing, was explored by comparing with the existing di-phenylene-diamine (DPD) TRO sensor. The results showed that the average TRO measurement deviation between the amperometric sensor and the DPD sensor was within ±10% in valid BE test cycles and the O&M testing exceeding 47 operating hours.
View Article and Find Full Text PDFJ Dev Orig Health Dis
January 2025
Department of Nutrition and Dietetics, Faculty of Health Sciences, Ankara University, Keçiören, Ankara, Turkey.
Breast milk (BM) is the only source of iodine and bioactive compounds that influence growth and development in infants. The content of BM may be influenced by maternal body mass index (BMI). The aim of this study was to investigate the effect of maternal weight on BM and cord blood iodine concentrations, growth-related hormones, infant anthropometric measurements.
View Article and Find Full Text PDFJ Phys Chem A
January 2025
Institute of Physical Chemistry, University of Göttingen, Tammannstrasse 6, 37077 Göttingen, Germany.
The persistent organic radical 2,2,6,6-tetramethylpiperidinyloxyl (TEMPO) protects its NO radical center by four methyl groups. Two of them are arranged tightly (t) on one side of the six-membered puckered heterocycle, and the other two more openly (o) on the other side. It is shown by OH stretching infrared spectroscopy in heated supersonic jet expansions that the hydrogen bond and aromatic ring of a first solvating benzyl alcohol have almost no preference for either side.
View Article and Find Full Text PDFACS Appl Nano Mater
March 2024
Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.
View Article and Find Full Text PDFFront Endocrinol (Lausanne)
January 2025
Department of Otolaryngology-Head and Neck Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning, China.
Background: Primary squamous cell carcinoma of the thyroid (PSCCT) has recently been reclassified as a morphologic pattern of anaplastic thyroid carcinoma (ATC). Consequently, PSCCT and squamous cell carcinoma with papillary thyroid carcinoma (SCC-PTC) were categorized as ATC. However, in terms of clinical characteristics and overall prognosis, whether PSCCT is similar to SCC-PTC has yet to be sufficiently investigated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!