Real-time imaging and quantitative analysis of internal gap formation in bulk-fill and conventional resin composites: An OCT evaluation.

Photodiagnosis Photodyn Ther

Department of Cariology & Endodontics, The Affiliated Stomatological Hospital, Jiangxi Medical College, Nanchang University, Nanchang 330006, Jiangxi, China; Jiangxi Province Key Laboratory of Oral Biomedicine, Nanchang 330006, Jiangxi, China. Electronic address:

Published: June 2024

Background: This study used optical coherence tomography (OCT) to observe real-time internal gap formation in both bulk-fill and conventional resin composites. It aimed to provide a quantitative analysis of variations, addressing the inconclusive nature of microleakage assessment caused by differences in testing methods.

Methods: Fifty extracted third molars prepared with Class I cavities, were divided into five groups (n = 10). Conventional resin Filtek Z350 XT (FZX) was applied with a double-layer filling of 2 mm per layer. Bulk-fill resins X-tra fil (XTF), Filtek Bulk Fill Posterior Restorative (FBP), Surefil SDR Flow + (SDR), and Filtek Flowable Restorative (FFR) were applied with a single-layer filling of 4 mm. Real-time OCT imaging was conducted during light curing. Post-curing, the entire sample was OCT-scanned. Following this, ImageJ software was used to measure the gap (G1 %). Subsequently, thermal cycling (TC) (5000 times, 5 °C-55 °C) was applied, followed by OCT scanning to calculate the gap (G2 %) and ΔG%. Data were analyzed using two-way repeated measures ANOVA, Kruskal-Wallis test, and Duncan's test (α=0.05).

Results: There was no significant difference in G1 % among the groups (p > 0.05). Following TC, FZX exhibited the highest G2 %, succeeded by FFR, FBP, XTF, and SDR, with SDR demonstrating the lowest G2 % (p < 0.05). FZX showed the highest ΔG% (p < 0.05), while SDR exhibited the lowest ΔG% (p < 0.05).

Conclusion: OCT proves to be a promising tool for detecting microleakage. TC exerted a more significant negative impact on conventional resin. Surefil SDR Flow + displayed the least microleakage, both before and after TC.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pdpdt.2024.104103DOI Listing

Publication Analysis

Top Keywords

conventional resin
16
quantitative analysis
8
internal gap
8
gap formation
8
formation bulk-fill
8
bulk-fill conventional
8
resin composites
8
surefil sdr
8
sdr flow
8
005 fzx
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!