Background: Highly porous metal tibial metaphyseal cones (TMCs) are commonly utilized in revision total knee arthroplasty (TKA) to address bone loss and obtain biologic fixation. Mid-term (5 to 10 year) studies have previously demonstrated excellent survivorship and high rates of osseointegration, but longer-term studies are lacking. We aimed to assess long-term (≥ 10 year) implant survivorship, complications, and clinical and radiographic outcomes after revision TKA with TMCs.
Methods: Between 2004 and 2011, 228 revision TKAs utilizing porous tantalum TMCs with stemmed tibial components were performed at a single institution and were retrospectively reviewed. The mean age at revision was 65 years, the mean body mass index was 33, and 52% were women. Implant survivorship, complications, and clinical and radiographic outcomes were assessed. The mean follow-up was 6.3 years.
Results: The 10-year survivorship free of aseptic loosening leading to TMC removal was 97%, free of any TMC removal was 88%, free of any re-revision was 66%, and free of any reoperation was 58%. The most common indications for re-revision were periprosthetic joint infection, instability, and aseptic femoral component loosening. The 10-year nonoperative complication rate was 24%. The mean Knee Society scores increased from 38 preoperatively to 69 at 10 years. There were 8 knees that had evidence of partial, progressive tibial radiolucencies at 10 years.
Conclusions: Porous tantalum TMCs demonstrated persistently durable longer-term survivorship with a low rate of implant removal. The rare implant removals for component loosening or instability were offset by those required for periprosthetic joint infection, which accounted for 80% of cone removals. Porous tantalum TMCs provide an extremely reliable tool to address tibial bone loss and achieve durable long-term fixation in revision TKA.
Level Of Evidence: IV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2024.04.059 | DOI Listing |
J Orthop Surg Res
December 2024
Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.
Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).
Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.
Langmuir
December 2024
Key Laboratory of Soft Chemistry and Functional Materials of Education Ministry, Nanjing University of Science and Technology, Nanjing 210094, China.
Traditional anodization was generally conducted in aqueous or water-containing solutions at room temperature or even lower temperatures. The two best known examples of the application of traditional anodization in the fabrication of nanostructured oxides are porous anodic alumina and titania nanotube films. In 1998, Melody et al.
View Article and Find Full Text PDFZhongguo Gu Shang
November 2024
Department of Joint Surgery, the 940th Hospital of PLA Joint Logistics Support Force, Lanzhou 730050, Gansu, China.
Objective: To explore the surgical technique and clinical outcomes of biological total hip arthroplasty(THA) combined with impacting bone grafting for the treatment of moderate to severe acetabular invagination secondary to rheumatoid arthritis(RA).
Methods: Total of 20 patients(28 hips) with RA secondary to acetabular invagination were treated with THA of bioprosthesis combined with autogenous bone grafting from January 2012 to October 2020, including 5 males(8 hips) and 15 females(20 hips) with an average age of (55.10±4.
BMC Musculoskelet Disord
November 2024
Center for Sports Medicine, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China.
Purpose: The conversion of knee arthrodesis to total knee arthroplasty (TKA) is a challenging procedure. This article aims to report a case of fusion knee with patellar absence who was converted to TKA and has achieved good results.
Methods: The patient, a 23 years old Tibetan Buddhist monk, sustained a left knee joint injury at the age of 12 due to a car accident, leading to subsequent knee arthrodesis at 18 years old as a result of recurrent severe infections.
J Arthroplasty
November 2024
Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom; University of Nottingham, Nottingham, United Kingdom.
Background: Trabecular metal is being increasingly used in primary total hip arthroplasty (THA). This study compared medium-term (< 15 years) outcomes of fiber mesh titanium and trabecular metal acetabular components.
Methods: This study included 6,563 patients who underwent primary THA with either fiber mesh titanium or trabecular metal-backed acetabular components.