SensAA-Design and Verification of a Cloud-Based Wearable Biomechanical Data Acquisition System.

Sensors (Basel)

Zentrum für Zuverlässige Mechatronische Systeme (ZMS), Aalen University, 73430 Aalen, Germany.

Published: April 2024

Exoskeletons designed to assist patients with activities of daily living are becoming increasingly popular, but still are subject to research. In order to gather requirements for the design of such systems, long-term gait observation of the patients over the course of multiple days in an environment of daily living are required. In this paper a wearable all-in-one data acquisition system for collecting and storing biomechanical data in everyday life is proposed. The system is designed to be cost efficient and easy to use, using off-the-shelf components and a cloud server system for centralized data storage. The measurement accuracy of the system was verified, by measuring the angle of the human knee joint at walking speeds between 3 and 12 km/h in reference to an optical motion analysis system. The acquired data were uploaded to a cloud database via a smartphone application. Verification results showed that the proposed toolchain works as desired. The system reached an RMSE from 2.9° to 8°, which is below that of most comparable systems. The system provides a powerful, scalable platform for collecting and processing biomechanical data, which can help to automize the generation of an extensive database for human kinematics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11053589PMC
http://dx.doi.org/10.3390/s24082405DOI Listing

Publication Analysis

Top Keywords

biomechanical data
12
data acquisition
8
system
8
acquisition system
8
daily living
8
data
6
sensaa-design verification
4
verification cloud-based
4
cloud-based wearable
4
wearable biomechanical
4

Similar Publications

Purpose: Asymmetric anterior closing-wedge high tibial osteotomy (ACWHTO) allows correction of both excessive posterior tibial slope (PTS) and varus deformity. However, the complexity of this surgery requires a high degree of accuracy, which is less likely to be achieved with standard instrumentations. This study aimed to determine the accuracy of 3D patient-specific cutting guides (PSCGs) to provide the accurate planned correction in the frontal and sagittal planes.

View Article and Find Full Text PDF

Objective: To provide clinicians with reliable recommendations for the selection of appropriate suturing techniques for surgical management of common musculoskeletal soft tissue injuries.

Methods: A systematic search of PubMed, Springer, Web Science, Vip Database, China National Knowledge, and Wanfang Data for in vitro biomechanical studies on suture techniques in the surgical treatment of musculoskeletal soft tissue injuries covering relevant studies from April 2009 to April 2024 was performed. A generalized classification was made based on the characteristics of the techniques, and recommendations for the selection of suture techniques were made according to the GRADE concept.

View Article and Find Full Text PDF

Treatment of limb skin defect with self-made skin distractor.

BMC Musculoskelet Disord

December 2024

Orthopedic Research Institute of HeBei Province, Orthopedic Biomechanic Key Laboratory of Hebei Province, Trauma Emergency Center of Third Hospital of Hebei Medical University, Shijiazhuang, 050051, China.

Objective: To investigate the effect of self-made skin distractor in the treatment of limb skin defects.

Methods: From September 2018 to January 2020, 15 cases of limb skin defects (16 wounds) were treated with self-designed skin distractor, including 13 males and 2 females, with an average age of 42 years (range, 9-73 years). The smallest area of skin defect was 6 cm×3 cm, the largest was 32 cm ×7 cm, with an average of 72.

View Article and Find Full Text PDF

There is a growing interest in the development of methods for the detection of nanoparticle (NP) toxicity to living organisms based on the analysis of relevant multidimensional data sets. In particular the detection of preliminary signs of NPs toxicity effects would benefit from the selection of data featuring NPs-induced alterations of biological barriers. Accordingly, we present an original Topological Data Analysis (TDA) of the nanomechanical properties of Escherichia coli cell surface, evaluated by multiparametric Atomic Force Microscopy (AFM) after exposure of the cells to increasing concentrations of titanium dioxide nanoparticles (TiONPs).

View Article and Find Full Text PDF

Order picking tasks require repetitive trunk and upper arms movements that may increase the risk of developing musculoskeletal disorders, particularly among older workers due to the decline of their physical capabilities with aging. We proposed an approach based on a limited number of wearable inertial sensors to assessed exposures to non-neutral trunk and upper arms postures among both older and young workers during their regular work-shifts. The obtained data were processed accordingly to international standards (ISO 11226 and EN 1005-4) to detect the existence of possible differences associated with age-specific working strategies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!