  • - A study was conducted to create a better method for evaluating the accuracy of 3D-printed dental models, aiming to guide dental practitioners in choosing the right printer.
  • - Researchers designed a specialized dental model with numerous measurable features and tested six different 3D printers, measuring linear dimensions and 3D errors like flatness and parallelism.
  • - Results showed the Objet30 Pro printer produced the most accurate models, with minimal deviations, highlighting variations in deformation patterns across different printers.

Article Abstract

(1) Background: Various 3D printers are available for dental practice; however, a comprehensive accuracy evaluation method to effectively guide practitioners is lacking. This in vitro study aimed to propose an optimized method to evaluate the spatial trueness of a 3D-printed dental model made of photopolymer resin based on a special structurized dental model, and provide the preliminary evaluation results of six 3D printers. (2) Methods: A structurized dental model comprising several geometrical configurations was designed based on dental crown and arch measurement data reported in previous studies. Ninety-six feature sizes can be directly measured on this original model with minimized manual measurement errors. Six types of photo-curing 3D printers, including Objet30 Pro using the Polyjet technique, Projet 3510 HD Plus using the Multijet technique, Perfactory DDP and DLP 800d using the DLP technique, Form2 and Form3 using the SLA technique, and each printer's respective 3D-printable dental model materials, were used to fabricate one set of physical models each. Regarding the feature sizes of the simulated dental crowns and dental arches, linear measurements were recorded. The scanned digital models were compared with the design data, and 3D form errors (including overall 3D deviation; flatness, parallelism, and perpendicularity errors) were measured. (3) Results: The lowest overall 3D deviation, flatness, parallelism, and perpendicularity errors were noted for the models printed using the Objet30 Pro (overall value: 45 μm), Form3 (0.061 ± 0.019 mm), Objet30 Pro (0.138 ± 0.068°), and Projet 3510 HD Plus (0.095 ± 0.070°), respectively. In color difference maps, different deformation patterns were observed in the printed models. The feature size proved most accurate for the Objet30 Pro fabricated models (occlusal plane error: 0.02 ± 0.36%, occlusogingival direction error: -0.06 ± 0.09%). (4) Conclusions: The authors investigated a novel evaluation approach for the spatial trueness of a 3D-printed dental model made of photopolymer resin based on a structurized dental model. This method can objectively and comprehensively evaluate the spatial trueness of 3D-printed dental models and has a good repeatability and generalizability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11053721PMC
http://dx.doi.org/10.3390/polym16081083DOI Listing

Publication Analysis

Top Keywords

dental model
32
spatial trueness
16
3d-printed dental
16
structurized dental
16
objet30 pro
16
dental
13
model photopolymer
12
photopolymer resin
12
trueness 3d-printed
12
model
9

Similar Publications

Introduction: Sarcoidosis is an inflammatory disease characterized by granulomas, the etiology of which remains unclear. This study examines sarcoidosis-related mortality trends in the United States from 1999 to 2020, with a focus on disparities pertaining to patient sex, geographical location, and urbanization status.

Methods: We analyzed death certificate data from the CDC WONDER database, using ICD-10 code D86.

View Article and Find Full Text PDF

Aims: The purpose of this systematic review was to assess the safety and effectiveness of beta antagonists for improving clinical care in burn patients, compared to placebo.

Methods: Articles from randomized-controlled trials were identified by a literature search on PubMed and Cochrane. We included relevant trials involving patients with burn.

View Article and Find Full Text PDF

Background: Peri-implantitis is characterized as a pathological change in the tissues around dental implants. Fourier-transform infrared spectroscopy (FTIR) provides molecular information from optical phenomena observed by the vibration of molecules, which is used in biological studies to characterize changes and serves as a form of diagnosis.

Aims: this case-control study evaluated the peri-implant disease by using FTIR spectroscopy with attenuated total reflectance in the fingerprint region.

View Article and Find Full Text PDF

A hallmark of chronic and inflammatory diseases is the formation of a fibrotic and stiff extracellular matrix (ECM), typically associated with abnormal, leaky microvascular capillaries. Mechanisms explaining how the microvasculature responds to ECM alterations remain unknown. Here, we used a microphysiological model of capillaries on a chip mimicking the characteristics of healthy or fibrotic collagen to test the hypothesis that perivascular cells mediate the response of vascular capillaries to mechanical and structural changes in the human ECM.

View Article and Find Full Text PDF

Natural bone is a self-regenerating nanocomposite made of proteins and minerals. Such self-regenerative capacity can be negatively affected by certain diseases involving the bone or its surrounding tissues. Our study assesses the ability of bone grafting material to regenerate bone in animals who have artificially created critical-sized defects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!