In the original publication [...].
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11055010 | PMC |
http://dx.doi.org/10.3390/nu16081186 | DOI Listing |
Radiat Prot Dosimetry
December 2024
Former staff of Secondary Standard Dosimetry Laboratory, Centro de Protección e Higiene de la Radiaciones, Carretera La Victoria II Km 2½, e/Monumental y Final, Guanabacoa, La Habana, 11100, Cuba.
The present work describes the results for the bilateral comparison between the Secondary Standards Dosimetry Laboratories of the Instituto Nacional de Investigaciones Nucleares (SSDL-ININ), Mexico, and the pilot laboratory, the Centro de Protección e Higiene de las Radiaciones (SSDL-CPHR), Cuba, for the realization of the air kerma (${\boldsymbol{K}}_{\boldsymbol{a}}$) quantity to: (i) diagnostic X-ray (DXR) IEC 61267:2005 beam qualities: RQR 5 RQR 9, RQT 8, and RQT 9 and (ii) radiation protection (RP) ISO 4037:2019 X-ray beam qualities: N60, N100, and W60, as well S-Cs for gamma radiation. The matched and characterized reference fields are realized at SSDL-ININ with a Toshiba E7252FX X-ray tube. In all cases, the ${\boldsymbol{K}}_{\boldsymbol{a}}$ measurements are traceable to PTB, except for S-Cs, traceable to ININ.
View Article and Find Full Text PDFPac Symp Biocomput
December 2024
Department of Biomedical Informatics, Harvard Medical School Boston, MA 02115, USA.
Accurately interpreting medical images and writing radiology reports is a critical but challenging task in healthcare. Both human-written and AI-generated reports can contain errors, ranging from clinical inaccuracies to linguistic mistakes. To address this, we introduce ReXErr, a methodology that leverages Large Language Models to generate representative errors within chest X-ray reports.
View Article and Find Full Text PDFUrol Case Rep
September 2024
University at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Department of Urology, Buffalo, NY, USA.
Ophthalmic Physiol Opt
November 2024
Dept. Física Aplicada, Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain.
Purpose: Investigations into the correction of presbyopia have considered lens design, clinical implications and the development of objective metrics such as the visual Strehl ratio. This study investigated the Jacobi-Fourier phase mask as an ophthalmic element in the correction of presbyopia. The goal was to develop a contact or intraocular lens whose performance was largely insensitive to changes in pupil diameter.
View Article and Find Full Text PDFInfect Dis Ther
October 2024
Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!