Chlorine ions play an important role in the corrosion of bronzeware. This study employs techniques such as XRD, OM, SEM, EBSD, and electrochemical testing to analyze the microstructure, crystal structure, chemical composition, and corrosion performance of bronze earrings unearthed at the Xindianzi site in Inner Mongolia. The results indicate the presence of work-hardened structures, including twinning and equiaxed crystals, on the earrings' surface. With an increase in chloride ion concentration in NaCl solutions from 10 mol/L to 1 mol/L, the corrosion current density of the bronze earrings increased from 2.372 × 10 A/cm to 9.051 × 10 A/cm, demonstrating that the alloy's corrosion rate escalates with chloride ion concentration. A 3-day immersion test in 0.5% NaCl solution showed the formation of a passivation layer of metal oxides on the earrings' surface. These findings underscore the significance of the impact chloride ions have on the corrosion of copper alloys, suggesting that activating the alloy's reactive responses can accelerate the corrosion process and provide essential insights into the corrosion mechanisms of bronze artifacts in chloride-containing environments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11051321 | PMC |
http://dx.doi.org/10.3390/ma17081734 | DOI Listing |
Sci Rep
January 2025
LCEA Laboratory, Faculty of Sciences, Mohammed Premier University, Oujda, Morocco.
In the current investigation, the efficiency inhibition of two newly synthesized bi-pyrazole derivatives, namely 2,3-bis[(bis((1 H-pyrazol-1-yl) methyl) amino)] pyridine (Tetra-Pz-Ortho) and 1,4-bis[(bis((1 H-pyrazol-1-yl) methyl) amino)] benzene (Tetra-Pz-Para) for corrosion of carbon steel (C&S) in 1 M HCl medium was evaluated. A Comparative study of inhibitor effect of Tetra-Pz-Ortho and Tetra-Pz-Para was conducted first using weight loss method and EIS (Electrochemical Impedance Spectroscopy) and PDP (Potentiodynamic Polarisation) techniques. Tetra-Pz-Ortho and Tetra-Pz-Para had a maximum inhibition efficacy of 97.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
January 2025
Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, 781039, Assam, India.
The adoption of carbon capture, utilization, and storage (CCUS) technology is increasingly prevalent, driven by the global initiative to conserve energy and reduce emissions. Nevertheless, CCUS has the potential to induce corrosion in equipment, particularly in high-pressure environments containing carbon dioxide (CO). Therefore, anti-corrosion protection is necessary for the metal utilized for CO production and storage equipment.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Bioorganic Laboratory, Department of Chemistry, University of Delhi, Delhi, India. Electronic address:
Corrosion is a significant issue affecting industrial metal surfaces, resulting in material degradation, economic losses, and safety concerns. This review comprehensively examines chitosan and its nano and bionanocomposite forms as sustainable, eco-friendly corrosion inhibitors, emphasizing key innovations in their development and application. The article highlights chitosan's ability to form protective films, which inhibit corrosion by creating a barrier on metal surfaces.
View Article and Find Full Text PDFJ Adv Res
January 2025
National Institute of Research and Development for Optoelectronics - INOE 2000, 409 Atomistilor St. 077125 Magurele, Romania. Electronic address:
Introduction: Chronic inflammation leading to implant failure present major challenges in orthopedics, dentistry, and reconstructive surgery. Titanium alloys, while widely used, often provoke inflammatory complications. Zinc-doped calcium phosphate (CaP) coatings offer potential to enhance implant integration by improving corrosion resistance, bioactivity, and immunocompatibility.
View Article and Find Full Text PDFJ Arthroplasty
January 2025
Oakland University William Beaumont School of Medicine, Rochester, MI; Department of Orthopedic Surgery, Corewell Health William Beaumont University Hospital, Royal Oak, MI. Electronic address:
Background: Hip instability following total hip arthroplasty (THA) is among the most common indications for revision surgery. The implantation of dual-mobility (DM) systems, designed to improve stability, continues to rise, and thus, characterizing in vivo implant damage modes is paramount.
Methods: Under an implant retrieval protocol, 51 DM THA systems were analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!