Primary Stability of Implants Inserted into Polyurethane Blocks: Micro-CT and Analysis In Vitro.

Bioengineering (Basel)

Department of Medicine, Surgery and Health Sciences, University of Trieste, Piazza dell'Ospitale 1, 34129 Trieste, Italy.

Published: April 2024

Unlabelled: The approach employed for the site preparation of the dental implant is a variable factor that affects the implant's primary stability and its ability to integrate with the surrounding bone. The main objective of this in vitro study is to evaluate the influence of different techniques used to prepare the implant site on the primary stability of the implant in two different densities of artificial bone.

Materials And Methods: A total of 150 implant sites were prepared in rigid polyurethane blocks to simulate two distinct bone densities of 15 pounds per cubic foot (PCF) and 30 PCF, with a 1-mm-thick simulated cortex. The implant sites were equally distributed among piezoelectric surgery (PES), traditional drills (TD), and black ruby magnetic mallet inserts (MM). Two methods have been employed to evaluate the implant's primary stability, Osstell and micro-tomography.

Results: In the present study, we observed significant variations in the implant stability quotient (ISQ) values. More precisely, our findings indicate that the ISQ values were generally higher for 30 PCF compared to 15 PCF. In terms of the preparation technique, PES exhibited the greatest ISQ values, followed by MM, and finally TD. These findings corresponded for both bone densities of 30 PCF (PES 75.6 ± 1.73, MM 69.8 ± 1.91, and TD 65.8 ± 1.91) and 15 PCF (PES 72.3 ± 1.63, MM 62.4 ± 1.77, and TD 60.6 ± 1.81). By utilizing Micro-CT scans, we were able to determine the ratio of the implant occupation to the preparation site. Furthermore, we could calculate the maximum distance between the implant and the wall of the preparation site. The findings demonstrated that PES had a higher ratio of implant to preparation site occupation, followed by TD, and then the MM, at a bone density of 30 PCF (PES 96 ± 1.95, TD 94 ± 1.88, and MM 90.3 ± 2.11). Nevertheless, there were no statistically significant differences in the occupation ratio among these three approaches in the bone density of 15 PCF (PES 89.6 ± 1.22, TD 90 ± 1.31, and MM 88.4 ± 1.17). Regarding the maximum gap between the implant and the site preparation, the smallest gaps were seen when TD were used, followed by MM, and finally by PES, either in a bone density 15 PCF (PES 318 ± 21, TD 238 ± 17, and MM 301 ± 20 μm) or in a bone density 30 PCF (PES 299 ± 20, TD 221 ± 16, and MM 281 ± 19 μm). A statistical analysis using ANOVA revealed these differences to be significant, with -values of < 0.05.

Conclusion: The outcomes of this study indicate that employing the PES technique and osteo-densification with MM during implant insertion may enhance the primary stability and increase the possibility of early implant loading.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11048430PMC
http://dx.doi.org/10.3390/bioengineering11040383DOI Listing

Publication Analysis

Top Keywords

pcf pes
24
primary stability
20
bone density
16
density pcf
16
implant
12
isq values
12
preparation site
12
pes
11
pcf
10
polyurethane blocks
8

Similar Publications

The role of linkers and frustrated lewis pairs catalysts in the formation of zwitterionic 1,2-anti-addition product with non-conjugated terminal diacetylenes: A computational study.

J Mol Graph Model

December 2024

Computation and Simulation Unit (Analytical & Environmental Science Division and Centralized Instrument Facility), CSIR-Central Salt & Marine Chemicals Research Institute, Bhavnagar, Gujarat, India, 364 002; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India. Electronic address:

This study presents a computational investigation into the mechanistic pathway and the linker units involved in forming the zwitterionic 1,2-anti-addition product of non-conjugated diacetylenes, di(propargyl)ether (DPE), di(prop-2yn-1yl)sulfane (DPS) and 1,6-Heptadiyne (HD) catalyzed by the inter-molecular phosphine/borane frustrated Lewis pairs (FLPs), i.e., PPh[CH(CF)](P-CF)/[B(CF)]([B]) and P(o-tolyl)(P-tol)/[B(CF)]([B]).

View Article and Find Full Text PDF

Primary Stability of Implants Inserted into Polyurethane Blocks: Micro-CT and Analysis In Vitro.

Bioengineering (Basel)

April 2024

Department of Medicine, Surgery and Health Sciences, University of Trieste, Piazza dell'Ospitale 1, 34129 Trieste, Italy.

Unlabelled: The approach employed for the site preparation of the dental implant is a variable factor that affects the implant's primary stability and its ability to integrate with the surrounding bone. The main objective of this in vitro study is to evaluate the influence of different techniques used to prepare the implant site on the primary stability of the implant in two different densities of artificial bone.

Materials And Methods: A total of 150 implant sites were prepared in rigid polyurethane blocks to simulate two distinct bone densities of 15 pounds per cubic foot (PCF) and 30 PCF, with a 1-mm-thick simulated cortex.

View Article and Find Full Text PDF

This paper investigates the stability of an incompressible viscous fluid flow between relatively moving horizontal parallel plates in the presence of a uniform vertical throughflow. A linear stability analysis has been performed by employing the method of normal modes and the resulting stability equation is solved numerically using the Chebyshev collocation method. Contrary to the stability of plane Couette flow (PCF) to small disturbances for all values of the Reynolds number in the absence of vertical throughflow, it is found that PCF becomes unstable owing to the change in the sign of growth rate depending on the magnitude of throughflow.

View Article and Find Full Text PDF

Introduction: One of the most common complications in the immediate and late postoperative period following total laryngectomy or pharyngolaryngectomy is pharyngocutaneous fistulae (PCF) formation and pharyngoesophageal stenosis (PES), causing significant mortality and morbidity. Since 1978, Montgomery salivary bypass tube (MSBT) has been used to reduce the incidence of PCF and PES. The aim of this retrospective study was to analyze the outcomes of using MSBT both as a tool to prevent PCF and PES and to treat these complications in the postoperative period.

View Article and Find Full Text PDF

Objective: To characterize pharyngocutaneous fistula (PCF) rates and functional outcomes following microvascular free tissue transfer (MVFTT) reconstruction of salvage total laryngectomy (STL) with a review of two different flap inset techniques and a review of the literature.

Methods: Retrospective review.

Results: Review of the literature revealed 887 patients who underwent STL MVFTT from 14 references.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!