Neonates with a new diagnosis of anorectal malformation (ARM) present a unique challenge to the clinical team. ARM is strongly associated with additional midline malformations, such as those observed in the VACTERL sequence, including vertebral, cardiac, and renal malformations. Timely assessment is necessary to identify anomalies requiring intervention and to prevent undue stress and delayed treatment. We utilized a multidisciplinary team to develop an algorithm guiding the midline workup of patients newly diagnosed with ARM. Patients were included if born in or transferred to our neonatal intensive care unit (NICU), or if seen in clinic within one month of life. Complete imaging was defined as an echocardiogram, renal ultrasound, and spinal magnetic resonance imaging or ultrasound within the first month of life. We compared three periods: prior to implementation (2010-2014), adoption period (2015), and delayed implementation (2022); ≤ 0.05 was considered significant. Rates of complete imaging significantly improved from pre-implementation to delayed implementation (65.2% vs. 50.0% vs. 97.0%, = 0.0003); the most growth was observed in spinal imaging (71.0% vs. 90.0% vs. 100.0%, = 0.001). While there were no differences in the rates of identified anomalies, there were fewer missed diagnoses with the algorithm (10.0% vs. 47.6%, = 0.05). We demonstrate that the implementation of a standardized algorithm can significantly increase appropriate screening for anomalies associated with a new diagnosis of ARM and can decrease delayed diagnosis. Further qualitative studies will help to refine and optimize the algorithm moving forward.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11049553PMC
http://dx.doi.org/10.3390/children11040494DOI Listing

Publication Analysis

Top Keywords

standardized algorithm
8
newly diagnosed
8
month life
8
complete imaging
8
delayed implementation
8
algorithm
5
development standardized
4
algorithm management
4
management newly
4
diagnosed anorectal
4

Similar Publications

Background: An all-inside endoscopic flexor hallucis longus (FHL) tendon transfer is indicated for the treatment of chronic, full-thickness Achilles tendon defects. The aim of this procedure is to restore function of the gastrocnemius-soleus complex while avoiding the wound complications associated with open procedures.

Description: This procedure can be performed through 2 endoscopic portals, a posteromedial portal (the working portal) and a posterolateral portal (the visualization portal).

View Article and Find Full Text PDF

A nomograph model for predicting the risk of diabetes nephropathy.

Int Urol Nephrol

January 2025

Medical College, Qinghai University, Xining, 810016, People's Republic of China.

Objective: Using machine learning to construct a prediction model for the risk of diabetes kidney disease (DKD) in the American diabetes population and evaluate its effect.

Methods: First, a dataset of five cycles from 2009 to 2018 was obtained from the National Health and Nutrition Examination Survey (NHANES) database, weighted and then standardized (with the study population in the United States), and the data were processed and randomly grouped using R software. Next, variable selection for DKD patients was conducted using Lasso regression, two-way stepwise iterative regression, and random forest methods.

View Article and Find Full Text PDF

Purpose: Congenital isolated adrenocorticotropic hormone deficiency (CIAD) is an autosomal recessive disorder. This study identifies novel TBX19 variants for CIAD patients, explores its possible effect mechanism at the structural, functional and protein levels, and guides clinicians better understand the condition.

Methods: The clinical characteristics of three CIAD children were summarized.

View Article and Find Full Text PDF

In multi-dimensional nanopositioning and nanomeasuring devices, interference measurement is widely used. The three-dimensional (3D) target mirror serves as the spatial reference plane to achieve multidimensional interference measurements. However, the surface shape errors of the target mirror are superimposed on the geometric dimensions of the measured workpiece, which limits the system's overall measurement accuracy.

View Article and Find Full Text PDF

In critically ill patients with atrial fibrillation (AF), standard treatment algorithms might not be applicable. Emergency departments (ED) play a crucial role in implementing individualized treatment approaches. The aim of this study was to assess the association of lactate and cardioversion success rates in AF patients presenting to an ED.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!