To practice standardized office blood pressure (OBP) measurement guidelines pragmatically, we developed an intelligent assisted OBP (IOBP) measurement system in the Chinese community, which can automatically obtain two or three BP values after a 5-min rest before the patients visit the doctor and transfer values to the community medical network in real time. We conducted a comparative study to investigate the agreement among IOBP, awake ambulatory BP (ABP), and conventional auscultatory OBP at different BP levels. Participants were divided into three groups according to BP, with 120/80 mmHg and 160/100 mmHg as the cut-off points. Attended IOBP, unattended IOBP, and auscultatory OBP were randomly measured before ABP monitoring. In total, 245 participants were included in the analysis. The mean systolic attended/unattended IOBP, auscultatory OBP, and awake ABP were 135.0, 136.7, 135.6, and 136.2 mmHg, respectively. Bland-Altman analysis revealed a bias of -1.1 and 0.5 mmHg for systolic attended/unattended IOBP compared with awake ABP in the overall sample. For auscultatory OBP, the bias was -0.4 (attended) and 1.2 mmHg (unattended). The discrepancy between the systolic attended/unattended IOBP and awake ABP was inconsistent at different BP levels. In Group 1 the values were -8.4 and -6.9 mmHg, whereas in Group 3, the values were 9.4 and 10.0 mmHg. BP measured using the IOBP measurement system was in accordance with awake ABP and conventional OBP, and can be a good choice in the Chinese community.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41440-024-01687-7 | DOI Listing |
Hypertens Res
July 2024
Department of Cardiovascular Medicine, Research Center for Hypertension Management and Prevention in Community, State Key Laboratory of Medical Genomics, Shanghai Key Laboratory of Hypertension, Shanghai Institute of Hypertension, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
To practice standardized office blood pressure (OBP) measurement guidelines pragmatically, we developed an intelligent assisted OBP (IOBP) measurement system in the Chinese community, which can automatically obtain two or three BP values after a 5-min rest before the patients visit the doctor and transfer values to the community medical network in real time. We conducted a comparative study to investigate the agreement among IOBP, awake ambulatory BP (ABP), and conventional auscultatory OBP at different BP levels. Participants were divided into three groups according to BP, with 120/80 mmHg and 160/100 mmHg as the cut-off points.
View Article and Find Full Text PDFHigh Blood Press Cardiovasc Prev
December 2019
Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Institute of Clinical Pharmacology and Toxicology, Charitéplatz 1, 10117, Berlin, Germany.
Introduction: The use of unattended automated office blood pressure (uAutoOBP) versus attended automated (aAutoOBP) and manual auscultatory office blood pressure (AuscOBP) measurements is a topic of current controversy.
Aim: To evaluate the differences between OBP measurements methods in the general practice (GP) setting.
Methods: We first compared aAutoOBP and uAutoOBP in 42 consecutive patients with hypertension (group 1).
J Clin Hypertens (Greenwich)
February 2019
Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
There is increasing interest in unattended automated office blood pressure (OBP) measurement, which gives lower blood pressure values than the conventional auscultatory OBP. Whether unattended automated OBP differs from standardized attended automated OBP performed using the same device and measurement protocol remains uncertain. A systematic review and meta-analysis of studies (aggregate data) comparing unattended vs attended automated OBP using the same device and measurement protocol (conditions, number of measurements, visits) was performed.
View Article and Find Full Text PDFJ Clin Hypertens (Greenwich)
December 2018
Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
The measurement of blood pressure in the office (OBP) remains the basis for hypertension diagnosis and management for more than half a century. Despite the increasing use of out-of-office blood pressure measurement using home and less so ambulatory monitoring and their endorsement by hypertension societies, at present and for some time to come it is likely that in many people the diagnosis and management of hypertension will be based on OBP measurement alone. OBP measurement is a very variable method affected by multiple factors, which have major impact on the OBP level, reproducibility and prognostic ability.
View Article and Find Full Text PDFJ Am Heart Assoc
April 2018
Department of Cardiology, Veterans Affairs and Georgetown University Medical Centers, Washington, DC.
Background: Automated office blood pressure (AOBP) measurement is superior to conventional office blood pressure (OBP) because it eliminates the "white coat effect" and shows a strong association with ambulatory blood pressure.
Methods And Results: We conducted a cross-sectional study in 146 participants with office hypertension, and we compared AOBP readings, taken with or without the presence of study personnel, before and after the conventional office readings to determine whether their variation in blood pressure showed a difference in blood pressure values. We also compared AOBP measurements with daytime ambulatory blood pressure monitoring and conventional office readings.