Establishment and preliminary evaluation of CT-based classification for distal radius fracture.

Sci Rep

Department of Orthopaedics, Beijing Chao-Yang Hospital, China Capital Medical University, Beijing, 100020, China.

Published: April 2024

Establish a new classification system of distal radius fracture based on computed tomographic (CT), and evaluate its reliability and reproducibility preliminarily, and provide a new theoretical reference for clinicians to use the clinical classification system. The imaging data and clinical data of 204 inpatients with distal radius fracture during 6 years from January 1, 2014 to January 1, 2019 in orthopaedic department were analyzed retrospectively and classified based on CT. Three observers evaluated the image data of 48 randomly selected cases based on CT at different time nodes of T1 and T2. Cohen's kappa was used to calculate the consistency. At the last follow-up, patients' Disabilities of the Arm, Shoulder and Hand (DASH), Patient Rated Wrist Evaluation (PRWE), and VAS scores were collected. Among 204 cases, there were 12 cases of type 1, including 6 cases of type 1-D, 4 cases of type 1-V and 2 cases of type 1-R. There were 6 cases of type 2, including 2 cases of type 2-DV, 2 cases of type 2-DR and 2 cases of type 2-VR. There were 186 cases of type 3, including 32 cases of type 3-0, 127 cases of type 3-1 and 27 cases of type 3-2. There was no significant difference in DASH, PRWE and VAS scores among all types (P > 0.05). The results of interobserver reproducibility were kappa = 0.985, ICC = 0.984 in the first evaluation, kappa = 0.986, ICC = 0.986 in the second evaluation. The results of intraobserver reproducibility were O1 = 0.991, O2 = 0.991, O3 = 0.989 respectively. The new classification system of distal radius fracture based on CT has theoretical and practical significance for incision selection, fracture reduction and internal fixation. 123 classification system is clear, comprehensive, easy to understand and remember. Moreover, it has higher interobserver reliability and intraobserver reproducibility than other systems reported at present.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11053106PMC
http://dx.doi.org/10.1038/s41598-024-60416-9DOI Listing

Publication Analysis

Top Keywords

cases type
48
distal radius
16
radius fracture
16
classification system
16
cases
14
type
12
type including
12
including cases
12
system distal
8
fracture based
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!