A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and testing of a high-precision generating voltmeter for metal-enclosed megavolt level DC voltage source. | LitMetric

Design and testing of a high-precision generating voltmeter for metal-enclosed megavolt level DC voltage source.

Rev Sci Instrum

State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Institute of High Voltage Technology, Xi'an Jiaotong University, Xi'an 710049, China.

Published: April 2024

An extremely stable megavolt (MV) level DC voltage source is the key foundation for many scientific instruments, and the need for accurate measurement and long-term real-time monitoring of its output voltage is increasingly urgent. The utilization of conventional resistive voltage dividers for measurements introduces leakage currents, resulting in considerable measurement errors. The non-contact generating voltmeter (GVM) sensor based on electric field measurement has a simple structure and a low cost, making it expected to be an effective solution. Currently, most research on GVM sensors focuses on the measurement of weak electric fields at kV/m levels with significant interference. In this paper, an improved high-precision non-contact GVM sensor was designed. A DC voltage test platform was built, and the effects of the sampling resistor and motor rotation speed on the measurement results were discussed. The relative combined uncertainty of the improved GVM sensor reached 0.042%, which satisfied the urgent need for MV level DC voltage source measurement. The improved GVM sensor can provide an effective reference for measuring the output voltage of a metal-enclosed MV level DC voltage source or the potential of a suspended electrode.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0190171DOI Listing

Publication Analysis

Top Keywords

level voltage
16
voltage source
16
gvm sensor
16
generating voltmeter
8
megavolt level
8
voltage
8
output voltage
8
improved gvm
8
measurement
6
gvm
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!