Introduction: Electrocautery with a snare probe offers a tool for the treatment of endobronchial polyps. The aim of this study was to demonstrate the efficacy of the snare probe in patients undergoing rigid bronchoscopy due to central airway obstruction.

Methods: This retrospective descriptive study included patients who underwent rigid bronchoscopy with an electrocautery snare probe for the diagnosis and/or treatment of endobronchial polyps in an interventional pulmonology unit.

Results: The mean age of the 47 patients (38 men) with endobronchial polypoid lesions was 61.5 years. Six lesions (12.8%) were located in the trachea, 6 (12.8%) in the right main bronchus, 11 (23.4%) in the left main bronchus, and 24 (51.1%) in the lobar bronchi. Twenty-eight lesions (59.5%) were malignant. Prior to the procedure, 6 (12.8%) patients had grade 1 obstruction, 6 (12.8%) had grade 2 obstruction, 15 (31.9%) had grade 3 obstruction, and 20 (42.6%) had grade 4 obstruction. In terms of airway obstruction after the procedure, grade 1 was present in 46 (97.9%) patients and grade 2 was present in 1 (2.1%) patient. No major complication developed in 93.6% of the patients. During a mean follow-up period of 48 months, 85.1% of the patients did not experience recurrence.

Conclusion: Our results demonstrate that the snare probe can be used to effectively and reliably establish airway patency in patients with central airway obstruction due to endobronchial polypoid lesions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resmer.2023.101074DOI Listing

Publication Analysis

Top Keywords

snare probe
16
grade obstruction
16
electrocautery snare
12
endobronchial polypoid
12
polypoid lesions
12
treatment endobronchial
8
endobronchial polyps
8
patients
8
rigid bronchoscopy
8
central airway
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!