Introduction: Wearable technology offers a promising solution to advance current rehabilitation strategies for post-operative orthopedic care. The aim of this study was to determine the level of agreement and concurrent validity of a smart knee brace compared to the gold standard measurement system GAITRite for assessing lower limb gait parameters.
Methods: Thirty-four healthy participants were fitted with the smart knee brace (Digital Knee) on their dominant limb. Gait parameters (stride length, stride time, and gait velocity) were measured simultaneously using the Digital Knee and the GAITRite electronic walkway. Two walks were performed at a comfortable speed and two at a fast-walking speed.
Results: At a comfortable walking speed, stride time was moderately valid (ICC = 0.66 s), and stride length and gait velocity demonstrated poor validity (ICC = 0.29; ICC = 0.41). All gait parameters demonstrated poor validity at a fast-walking speed (ICC = -0.16 to -0.01). Bias ranged from -0.08 to 0.28, with more clinically acceptable percentage errors at a comfortable walking speed (14.1-30%) versus at a fast-walking speed (26.4-42.6%). Gait velocity and stride length had substantially higher biases in the fast-walking speed compared to the comfortable walking speed (0.28 ± 0.39 m s vs. 0.02 ± 0.21 m s; 0.15 ± 0.23 m vs. -0.04 ± 0.17 m). Limits of agreement were considered narrower for stride time compared to stride length and gait velocity.
Conclusion: The Digital Knee is a promising approach to improving post-operative rehabilitation outcomes in patients with osteoarthritis. The Digital Knee demonstrated good agreement and moderate concurrent validity for measuring gait metrics at a comfortable walking speed. These findings highlight the opportunity of the wearable sensor as an intervention for post-operative orthopedic care. This was a laboratory-based study; thus, further research is required to validate the wearable sensor in real-world contexts and in patients with knee pathologies. Further, refinement of the algorithm for measuring gait metrics at slow- and fast-walking speed with the Digital Knee is warranted.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11037895 | PMC |
http://dx.doi.org/10.1159/000538487 | DOI Listing |
Sci Rep
January 2025
Department of Radiology, The First Affiliated Hospital, Hengyang Medical School, University of South China, Chuanshan Road No. 69, Hengyang, 421001, Hunan, China.
To determine the diagnostic performance of dual-energy CT (DECT) virtual noncalcium (VNCa) technique in the detection of bone marrow lesions (BMLs) in knee osteoarthritis, and further analyze the correlation between the severity of BMLs on VNCa image and the degree of knee pain. 23 consecutive patients with clinically diagnosed knee osteoarthritis were underwent DECT and 3.0T MRI between August 2017 and November 2018.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
January 2025
Department of Joint Surgery and Sports Medicine, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.
Purpose: This study aimed to investigate whether combining the analysis of different magnetic resonance imaging (MRI) signs enhances the diagnostic accuracy of lateral meniscus posterior root tears (LMPRTs) in patients with anterior cruciate ligament (ACL) injuries. We hypothesised that analysing the cleft, ghost and truncated triangle signs and lateral meniscus extrusion (LME) measurement together would improve the preoperative MRI-based diagnosis of LMPRTs.
Methods: This retrospective study used prospectively collected registry data from two academic centres, including patients undergoing primary or revision ACL reconstruction (ACLR) and LMPRT repair.
Medicina (Kaunas)
January 2025
Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul 06591, Republic of Korea.
: Despite its advantages, lateral close-wedge high tibial osteotomy (LCWHTO) requires proximal tibiofibular joint detachment (PTFJD) or fibular shaft osteotomy for gap closing. These fibula untethering procedures are technically demanding and not free from the risk of neurovascular injuries. Our novel fibula untethering technique, tibial-sided osteotomy (TSO) near the proximal tibiofibular joint (PTFJ), aims to reduce technical demands and the risk of injury to the peroneal nerve and popliteal neurovascular structures.
View Article and Find Full Text PDFJ Endovasc Ther
January 2025
Department of Vascular Surgery, Zuyderland Medical Centre, Heerlen, The Netherlands.
Objective: The gold standard imaging modality for assessing crural arterial disease is digital subtraction angiography (DSA). Using DSA, the operator can estimate the diameter and degree of stenosis and determine the diameter of the balloon. Since these measures are estimates, it allows for interobserver and intraobserver variability.
View Article and Find Full Text PDFDespite an increasing number of studies examining the effect of Single-Photon Emission Computed Tomography/ Computed Tomography (SPECT/CT) on improvement of diagnosis of aseptic loosening, there is still a great deal of uncertainty regarding its applicability in diagnostic algorithm. Therefore, in this meta-analysis, we aimed to investigate the diagnostic performance of SPECT/CT for identification of aseptic loosening in patients with persistent pain following the total knee arthroplasty (TKA) and total hip arthroplasty (THA). Electronic databases including Medline, Scopus, Web of Science, Cochrane library, and Embase were systematically searched for identifying relevant published studies from their inception to April 2023.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!