Aims: Delineation variations and organ motion produce difficult-to-quantify uncertainties in planned radiation doses to targets and organs at risk. Similar to manual contouring, most automatic segmentation tools generate single delineations per structure; however, this does not indicate the range of clinically acceptable delineations. This study develops a method to generate a range of automatic cardiac structure segmentations, incorporating motion and delineation uncertainty, and evaluates the dosimetric impact in lung cancer.
Materials And Methods: Eighteen cardiac structures were delineated using a locally developed auto-segmentation tool. It was applied to lung cancer planning CTs for 27 curative (planned dose ≥50 Gy) cases, and delineation variations were estimated by using ten mapping-atlases to provide separate substructure segmentations. Motion-related cardiac segmentation variations were estimated by auto-contouring structures on ten respiratory phases for 9/27 cases that had 4D-planning CTs. Dose volume histograms (DVHs) incorporating these variations were generated for comparison.
Results: Variations in mean doses (Dmean), defined as the range in values across ten feasible auto-segmentations, were calculated for each cardiac substructure. Over the study cohort the median variations for delineation uncertainty and motion were 2.20-11.09 Gy and 0.72-4.06 Gy, respectively. As relative values, variations in Dmean were between 18.7%-65.3% and 7.8%-32.5% for delineation uncertainty and motion, respectively. Doses vary depending on the individual planned dose distribution, not simply on segmentation differences, with larger dose variations to cardiac structures lying within areas of steep dose gradient.
Conclusion: Radiotherapy dose uncertainties from delineation variations and respiratory-related heart motion were quantified using a cardiac substructure automatic segmentation tool. This predicts the 'dose range' where doses to structures are most likely to fall, rather than single DVH curves. This enables consideration of these uncertainties in cardiotoxicity research and for future plan optimisation. The tool was designed for cardiac structures, but similar methods are potentially applicable to other OARs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clon.2024.04.002 | DOI Listing |
J Am Coll Surg
January 2025
Department of Surgery, The Ohio State University Wexner Medical Center and James Comprehensive Cancer Center, Columbus, OH.
Introduction: We aimed to investigate the geographic variation of Academic Medical Centers (AMCs) across different healthcare markets and the impact on surgical outcomes in nearby non-AMCs.
Methods: Patients who underwent major surgery between 2016 and 2021 were identified from the Medicare Standard Analytic Files. Healthcare markets were delineated using Dartmouth Atlas hospital referral regions.
Phys Imaging Radiat Oncol
January 2025
Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.
Background And Purpose: A novel ring-gantry cone-beam computed tomography (CBCT) imaging system shows improved image quality compared to its conventional version, but its effect on autosegmentation is unknown. This study evaluates the impact of this high-performance CBCT on autosegmentation performance, inter-observer variability, contour correction times and delineation confidence, compared to the conventional CBCT.
Materials And Methods: Twenty prostate cancer patients were enrolled in this prospective clinical study.
Heliyon
January 2025
Center for Research in Geospatial Data and Intelligence, Department of Geomatics Sciences, Université Laval, 1055, Avenue Du Séminaire, Québec, QC, Canada.
To reach a destination within the community, it is crucial that wheelchair users possess the ability to plan, execute, and acquire knowledge of routes in a safe and efficient manner. While numerous methods have been introduced for assessing the accessibility of sidewalks, existing studies often overlook the variations in the perception of the accessibility of long segments based on each wheelchair user's capabilities. Extended distances may lead to increased fatigue, impacting the ability of individuals with mobility disabilities to navigate sidewalks comfortably and independently.
View Article and Find Full Text PDFSensors (Basel)
January 2025
National Key Laboratory of Multispectral Information Intelligent Processing Technology, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan 430000, China.
Despite rapid progress in UAV-based infrared vehicle detection, achieving reliable target recognition remains challenging due to dynamic viewpoint variations and platform instability. The inherent limitations of infrared imaging, particularly low contrast ratios and thermal crossover effects, significantly compromise detection accuracy. Moreover, the computational constraints of edge computing platforms pose a fundamental challenge in balancing real-time processing requirements with detection performance.
View Article and Find Full Text PDFGenome Biol
January 2025
Center for Communicable Disease Dynamics, Department of Epidemiology, Harvard TH Chan School of Public Health, Boston, MA, USA.
Background: Genetic discontinuity represents abrupt breaks in genomic identity among species. Advances in genome sequencing have enhanced our ability to track and characterize genetic discontinuity in bacterial populations. However, exploring the degree to which bacterial diversity exists as a continuum or sorted into discrete and readily defined species remains a challenge in microbial ecology.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!