Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Measuring spinal alignment with radiological parameters is essential in patients with spinal conditions likely to be treated surgically. These evaluations are not usually included in the radiological report. As a result, spinal surgeons commonly perform the measurement, which is time-consuming and subject to errors. We aim to develop a fully automated artificial intelligence (AI) tool to assist in measuring alignment parameters in whole-spine lateral radiograph (WSL X-rays).
Methods: We developed a tool called Vertebrai that automatically calculates the global spinal parameters (GSPs): Pelvic incidence, sacral slope, pelvic tilt, L1-L4 angle, L4-S1 lumbo-pelvic angle, T1 pelvic angle, sagittal vertical axis, cervical lordosis, C1-C2 lordosis, lumbar lordosis, mid-thoracic kyphosis, proximal thoracic kyphosis, global thoracic kyphosis, T1 slope, C2-C7 plummet, spino-sacral angle, C7 tilt, global tilt, spinopelvic tilt, and hip odontoid axis. We assessed human-AI interaction instead of AI performance alone. We compared the time to measure GSP and inter-rater agreement with and without AI assistance. Two institutional datasets were created with 2267 multilabel images for classification and 784 WSL X-rays with reference standard landmark labeled by spinal surgeons.
Results: Vertebrai significantly reduced the measurement time comparing spine surgeons with AI assistance and the AI algorithm alone, without human intervention (3 minutes vs. 0.26 minutes; P < 0.05). Vertebrai achieved an average accuracy of 83% in detecting abnormal alignment values, with the sacral slope parameter exhibiting the lowest accuracy at 61.5% and spinopelvic tilt demonstrating the highest accuracy at 100%. Intraclass correlation analysis revealed a high level of correlation and consistency in the global alignment parameters.
Conclusions: Vertebrai's measurements can accurately detect alignment parameters, making it a promising tool for measuring GSP automatically.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2024.04.091 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!