Child impeding packs are difficult for children to open so protect them from unintended access to hazardous contents inside the pack. However, if packs are difficult for adults to open, in normal usage scenarios, this may result in a higher occurrence of packs being left open. This research explores differences in ease of usage and closure compliance between two types of child impeding packs of liquid laundry detergent capsules. The two packs, "Pinch & Lift" and "Press & Lift", had different opening and closing mechanisms. "Press & Lift" also included an audible "click" signal to confirm complete closure to the user. The research was performed across two studies. In both studies, the packs were used in participants' homes according to their usual storage and usage practices as replacements to their current liquid laundry detergent capsule pack. All participants had small children living with them in their household. In Study 1, self-reported closure and ease of use data was collected from 99 adult participants in Germany. They used each package in their home for 10 days. Study 2 extended Study 1 by measuring closure rates with an objective assessment using in pack sensors for a 10-day period for each pack. Self-reported closure and ease of use data were also collected. Study 2 was conducted with 87 participants in the United Kingdom. Results across both studies showed "Press & Lift" with the audible "Click" close signal to be rated by participants to be significantly easier to open and close and have a higher self-reported closure rate than "Pinch & Lift". In addition, Study 2 results demonstrated higher closure rates using "Press & Lift" based on the sensor-measured closure compliance. Together, the results suggest transition to a pack with a mechanism that is child impeding and easier for an adult to use with an audible closure signal, like the "Press & Lift" system, has potential to reduce child access to a capsule from a pack by reducing the likelihood of the pack being left open by the adult user. Ultimately, such packs could protect children from potential poisoning injury across a range of consumer products.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11034662 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0284346 | PLOS |
PLoS One
April 2024
Procter and Gamble, Strombeek Bever, Belgium.
Child impeding packs are difficult for children to open so protect them from unintended access to hazardous contents inside the pack. However, if packs are difficult for adults to open, in normal usage scenarios, this may result in a higher occurrence of packs being left open. This research explores differences in ease of usage and closure compliance between two types of child impeding packs of liquid laundry detergent capsules.
View Article and Find Full Text PDFJ Strength Cond Res
April 2024
Department of Public Health and Exercise Science, Appalachian State University, Boone, North Carolina; and.
Fiedler, MJ, Triplett, NT, Hamilton, KC, Needle, AR, and van Werkhoven, H. The effect of different weight plate widths (bumper vs. standard) on the biomechanics of the bench press.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
February 2023
ReSurg SA, Rue Saint Jean 22, 1260, Nyon, Switzerland.
Purpose: To synthesize the literature and critically appraise current evidence to determine the most accurate physical examination (clinical test or ultrasound) to detect pathologies of the long head of the biceps tendon (LHBT).
Methods: A search was performed on PubMed, Embase®, and Cochrane. Studies that compared the diagnostic accuracy of clinical tests or ultrasound versus arthroscopy for the assessment of LHBT pathologies were included.
Int Orthop
January 2021
Alps Surgery Institute, Clinique Générale d'Annecy, 4 Chemin de la Tour la Reine, 74000, Annecy, France.
Purpose: Management of the subscapularis tendon during anatomic total shoulder arthroplasty (TSA) remains controversial. In our unit, subscapularis tenotomy is the preferred technique; however, the potential for tendon gapping and failure is recognised. The purpose of this study is to describe and provide early clinical results of a novel, laterally based V-shaped tenotomy (VT) technique hypothesised to provide greater initial repair strength and resistance to gapping than a transverse tenotomy (TT), with both clinically and radiologically satisfactory post-operative tendon healing and function.
View Article and Find Full Text PDFSports Health
December 2020
Department of Orthopedics, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.
Context: There is a renewed interest in diagnosing and treating subscapularis tears, but there is a paucity of clinical guidance to optimize diagnostic decision-making.
Objective: To perform a literature review to evaluate advanced maneuvers and special tests in the diagnosis of subscapularis tears and create a diagnostic algorithm for subscapularis pathology.
Data Sources: PubMed, MEDLINE, Ovid, and Cochrane Reviews databases.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!