Monomethyl auristatin E (MMAE) has been used as a payload for several Food and Drug Administration (FDA) approved antibody-drug conjugates (ADCs). It is known that MMAE is released from the ADC following binding, internalisation and proteolytic degradation in target tissues. A striking discrepancy in systemic MMAE levels has been observed across species with 50-fold higher MMAE levels in human than that in rodents when normalised by ADC dose with unknown mechanism. Multiple factors could affect systemic MMAE levels such as production and elimination of unconjugated MMAE following ADC dosing. In this study, we have explored whether MMAE displays differential red blood cell (RBC) partitioning across species that may contribute to the different MMAE levels seen between human and animals. To determine MMAE RBC partitioning, tritium labelled MMAE ([H]-MMAE) was incubated in whole blood from mice, rats, monkeys and humans , then RBC partitioning was determined and compared across species. To test whether MMAE released from the ADC would show any difference in RBC partitioning, pinatuzumab vedotin or polatuzumab vedotin was administered to mice, rats, and monkeys. MMAE levels were measured in both blood and plasma, and the ratios of MMAE levels were calculated as blood-to-plasma ratio ( RBC partitioning). Our data showed that unconjugated MMAE has a species-dependent RBC partitioning with strong RBC partitioning in mouse, rat, followed by monkey blood, whereas minimal RBC partitioning was seen in human blood. Incubation of 2 nM of MMAE in mouse blood resulted in a blood-to-plasma ratio of 11.8 ± 0.291, followed by rat, monkey, and human at 2.36 ± 0.0825, 1.57 ± 0.0250, and 0.976 ± 0.0620, respectively. MMAE RBC partitioning is also concentration-dependent, with an inverse relationship between RBC partitioning and MMAE concentration (higher RBC partitioning at lower concentration). dosing of pinatuzumab vedotin in mouse displayed systemic MMAE at about a 5-fold higher blood concentration compared to plasma concentration once MMAE reached a pseudo-equilibrium, while systemic MMAE from blood and plasma concentration showed a 1.65-fold difference in rat. These data demonstrated that MMAE has a distinct RBC partitioning across different species, which may contribute to, at least in part, to the differential in the systemic MMAE levels observed between preclinical and clinical studies. These findings highlight the importance of fully characterising the ADME properties of both the ADC and its payload, to enable better translation from animals to human for ADC development.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00498254.2024.2345849DOI Listing

Publication Analysis

Top Keywords

rbc partitioning
48
mmae levels
28
mmae
23
systemic mmae
20
partitioning
13
rbc
12
blood
9
monomethyl auristatin
8
auristatin mmae
8
mmae payload
8

Similar Publications

Purpose: To present a first principle-based, high-fidelity computational model for predicting full three-dimensional (3D) and time-resolved retinal microvascular hemodynamics taking into consideration the flow and deformation of individual blood cells.

Methods: The computational model is a 3D fluid-structure interaction model based on combined finite volume/finite element/immersed-boundary methods. Three in silico microvascular networks are built from high-resolution in vivo motion contrast images of the superficial capillary plexus in the parafoveal region of the human retina.

View Article and Find Full Text PDF

Derivation of Russian-specific reference intervals for complete blood count, iron markers and related vitamins.

PLoS One

September 2024

Russian Medical Academy of Continuing Professional Education of the Ministry of Health, Moscow, Russia.

Objectives: This study aimed to establish reference intervals (RIs) for Russian adults for hematological parameters including related iron markers and vitamins. Sources of variation of reference values (RVs) and needs for secondary exclusion were explored for proper derivations of RIs.

Methods: Following the harmonized protocol of the IFCC Committee on Reference Intervals and Decision Limits (C-RIDL), 506 healthy Russians (age 18-80; 46% male) were recruited.

View Article and Find Full Text PDF

Despite increased interest in the effect of lingering red blood cells (LRBCs) on the heterogeneous hematocrit distribution in the microcirculation, quantitative data on LRBCs before and after the lingering event are still limited. The aim of the study was to investigate the relation between red blood cell (RBC) lingering and hematocrit partitioning in a microfluidic model of a microvascular bifurcation in the limit of low hematocrit conditions (tube hematocrit <10%). To this end, the classification of LRBCs was performed based on timing, position, and velocity of the RBCs.

View Article and Find Full Text PDF

Nanocarriers' repartitioning of drugs between blood subcompartments as a mechanism of improving pharmacokinetics, safety, and efficacy.

J Control Release

October 2024

Department of Pharmacology, The Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA; Department of Medicine, University of Pennsylvania, Philadelphia, PA, USA. Electronic address:

For medical emergencies, such as acute ischemic stroke, rapid drug delivery to the target site is essential. For many small molecule drugs, this goal is unachievable due to poor solubility that prevents intravenous administration, and less obviously, by extensive partitioning to plasma proteins and red blood cells (RBCs), which greatly slows delivery to the target. Here we study these effects and how they can be solved by loading into nanoscale drug carriers.

View Article and Find Full Text PDF

Introduction: Reticulocyte count and novel derived parameters provide insight into the effectiveness of erythropoiesis and may be useful tools in the classification and diagnosis of anemias. However, there is no standardisation, so we consider it necessary that each laboratory evaluates the parameters according to its own methodology and instrumentation and establishes its own reference ranges. Our aim was to establish the reference intervals (RIs) of reticulocyte profile provided by the Beckman Coulter DxH 900 haematological autoanalyzer in our reference population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!